Analysis of surface roughness in optical coherence elastography using a novel phantom

13Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : au, pl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Compression optical coherence elastography (OCE) has shown promise in detecting diseases, such as breast cancer, based on changes in the elasticity of tissue. While the mechanical models used in OCE assume a flat surface, tissue typically exhibits surface topography that can lead to inaccurate estimation of elasticity in OCE images (elastograms). The coupling of surface topography and heterogeneous mechanical properties in tissue make it challenging to study the relative impact of surface roughness on image formation. To address this, we developed mechanically homogeneous phantoms that accurately replicate the surface topography of human breast tissue. Surface topography of breast tissue specimens was captured in three-dimensional (3-D) optical coherence tomography (OCT) scans. Molds replicating the surface roughness of tissue were generated using 3-D modelling and 3-D printing. The phantoms were then fabricated in the molds using polydimethylsiloxane. OCT was used to validate the accuracy of the phantom surface topography and the phantoms were then used to determine the impact of surface roughness in compression OCE elastograms. Surface roughness phantoms were shown to accurately reflect the surface topography of six breast tissue specimens with a correlation of 0.96 ± 0.03. When imaged with a variant of compression OCE called quantitative micro-elastography, surface roughness resulted in a slight decrease in elasticity accuracy with a mean percentage error of 8.2 % for a flat phantom compared to 11.7 % for the roughness phantom, and a larger decrease in elasticity precision, or sensitivity, with a mean relative standard deviation of 9.4 % for the flat phantom compared to 21.2 %, for the roughness phantom. Our results show that contrast in elastograms moderately correlated with the phantom surface profile (r = 0.59, p < 0.001) and that surface roughness introduces spatially-varying elasticity that should be considered in the analysis of elastograms in compression OCE.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Analysis of surface roughness in optical coherence elastography using a novel phantom
Date Crossref
01/02/2024
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ultrasound Imaging and ElastographyPhotoacoustic and Ultrasonic ImagingOptical Coherence Tomography Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.