A novel method for assessment of airway opening pressure without the need for low-flow insufflation

25Citations signalées, ce qui n’est pas une note de qualité
9Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. Objectives To validate the conductive pressure ( P cond ) method, which compare the P cond —defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP—to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. Methods The proof-of-concept of the P cond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the P cond method was compared with the standard low-flow method. Measurements and main results Bench assessments validated the P cond method proof-of-concept. Sensitivity and specificity of the P cond method for AOP detection were 93% and 91%, respectively. AOP obtained by P cond and standard low-flow methods strongly correlated ( r = 0.84, p < 0.001). Changes in SpO 2 were significantly lower during P cond than during standard method ( p < 0.001). Conclusion Determination of P cond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A novel method for assessment of airway opening pressure without the need for low-flow insufflation
Date Crossref
07/07/2023
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Respiratory Support and MechanismsHemodynamic Monitoring and TherapyAirway Management and Intubation Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.