Aller au contenu principal
Accès ouvert déclaré 2023 conference-abstract

P102 DIFFERENCES IN HIGH–DENSITY MAPPING OF KOCH‘S TRIANGLE DURING TYPICAL AV NODAL REENTRANT TACHYCARDIA INTEGRATED AND NOT INTEGRATED WITH DIRECT RECORDING OF ATRIOVENTRICULAR NODE STRUCTURES POTENTIAL: A MULTICENTER NON–RANDOMIZED STUDY

0Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Despite the sustained efforts and advances in the fields of anatomy, histology, immunohistochemistry and cardiac mapping, the definition of the AVNRT circuit in humans is still incomplete. This discouraging result can be explained by many reasons, but the most important one has been the impossibility to map the AVNRT circuit without recording the electrical activity of the AVN and its extensions, which represent the diastolic interval in the tachycardia cycle. The aim of this study was to compare high density activation mapping integrated and not integrated with AV node potential recordings to establish the importance of annotation of AV nodal structure electrical activity in defining Koch’s triangle activation during AVNRT. Methods Electroanatomic 3–D reconstruction and propagation automated mapping of atrial activation during both sinus rhythm and tachycardia was performed using a basket catheter (64 electrodes of 0.4–mm2 area; 2.5–mm spacing, Orion, Boston Scientific, Natick, MA) and the Rhythmia electroanatomic mapping system in group 1 patients (X). In group 2 patients (45) the AV node potential (a very low frequency signal distinct from atrial, His bundle or ventricular activations, recorded from electrodes overlying the region of the compact AV node and its extensions by using a non–conventional bipolar electrogram filtering of [0.05/1 – 250] Hz) were also recorded both during slow fast AVNRT. Results The integrated map showed that during AVNRT, the activation wavefront descends from the Tendon of Todaro region (fast pathway area) and rises along the septal leaflet of the tricuspid valve through the RINE and reaches the AV bundle probably via the LNB bypassing the compact AV node almost completely. This kind of activation of the Koch’s triangle was not reconstructed by the non–integrated map. Moreover, the recording of the potentials of the AV node structures makes it possible to obtain a 100% coverage of the tachycardia cycle which was only 32% in the non–integrated maps (p < 0.0001). Conclusion The recording of the electrical activity of AV nodal structures allows a better definition of the circuit of typical slow–fast AVNRT which, in the majority of the cases, is completely localised in the right atrium.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
P102 DIFFERENCES IN HIGH–DENSITY MAPPING OF KOCH‘S TRIANGLE DURING TYPICAL AV NODAL REENTRANT TACHYCARDIA INTEGRATED AND NOT INTEGRATED WITH DIRECT RECORDING OF ATRIOVENTRICULAR NODE STRUCTURES POTENTIAL: A MULTICENTER NON–RANDOMIZED STUDY
Date Crossref
01/05/2023
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.