Aller au contenu principal
2023 conference-paper

Physical dose modeling and throughput optimization in EUV computational lithography

2Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Despite being crucial in an optical lithography process, “dose” has remained a relative concept in the computational lithography regime. It usually takes the form of a percentage deviation from a pre-identified “nominal condition” under the same illumination shape. Dose comparison between different illumination shapes has never been rigorously defined and modeled in numerical simulation to date. On the other hand, the exposure-limited nature of EUV lithography throughput demands the * illumination shape being optimized with the physical dose impact consciously taken into consideration. When the projection pupil is significantly obscured (as in the ASML EXE high NA scanner series), the lack of a proper physical dose constraint may lead to suboptimal energy utilization during exposure. In this paper, we demonstrate a method to accurately model the physical dose in an optical lithography process. The resultant dose concept remains meaningful in the context of a changing illumination pupil, which enables co-optimization of imaging quality and a throughput metric during the Source-Mask Optimization (SMO) phase, known as the Dose-Aware SMO. With a few realistic test cases we demonstrate the capability of Dose-Aware SMO in terms of improving EUV throughput via reducing the effective exposure time, in both regular and obscured projection systems. The physical dose modeling capability in computational lithography not only addresses those immediate challenges emergent from EUV throughput, but also opens the gate towards a broad class of exciting topics that are built upon physical dose, such as optical stochastic phenomena and so on.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Physical dose modeling and throughput optimization in EUV computational lithography
Date Crossref
28/04/2023
Éditeur
SPIE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advancements in Photolithography TechniquesMedical Imaging Techniques and ApplicationsElectron and X-Ray Spectroscopy Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.