A new imaging modality (viz., Long-Film [LF]) for acquiring long-length tomosynthesis images of the spine was recently enabled on the O-arm™ system and used in an IRB-approved clinical study at our institution. The work presented here implements and evaluates a combined image synthesis and registration approach to solve multi-modality registration of MR and LF images. The approach is well-suited for pediatric cases that use MR for preoperative diagnosis and aim for lower levels of intraoperative radiation exposure. A patch-based conditional GAN was used to synthesize 3D CT images from MR. The network was trained on deformably co-registered MR and CT image pairs. Synthesized images were registered to LF images using a model-based 3D-2D registration algorithm. Images from our clinical study were manually labeled, and the intra-user variability in anatomical landmark definition was measured in a simulation study. Geometric accuracy of registrations was evaluated on anatomical landmarks in separate test cases from the clinical study. The synthesis process generated CT images with clear bone structures. Analysis of manual labeling revealed 3.1±2.2 mm projection distance error between 3D and 2D anatomical landmarks. Anatomical MR landmarks projected on lateral LF images demonstrated a median projection distance error of 3.6 mm after registration. This work constitutes the first reported approach for MR to LF registration based on deep image synthesis. Preliminary results demonstrated the feasibility of globally rigid registration in aligning preoperative MR and intraoperative LF images. Work currently underway extends this approach to vertebra level, locally rigid / globally deformable registrations, with initialization based on automatically labeled vertebrae levels.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multi-modality registration of preoperative MR and intraoperative long-length tomosynthesis using GAN synthesis and 3D-2D registration
Date Crossref
03/04/2023
Éditeur
SPIE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Imaging and AnalysisMedical Image Segmentation TechniquesAnatomy and Medical Technology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.