Performance Assessment of Three Continuous Glucose Monitoring Systems in Adults With Type 1 Diabetes
Rattachement africain : de, ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: FIND, the global alliance for diagnostics, identified the nonmarket-approved continuous glucose monitoring (CGM) system, FiberSense system (FBS), as a potential device for use in low- and middle-income countries. Together with two market-approved, factory-calibrated CGM systems, namely, the FreeStyle Libre 2 (FL2) and the GlucoRx AiDEX (ADX), the FBS was subjected to a clinical performance evaluation. METHODS: Thirty adult participants with type 1 diabetes were enrolled. The study was mainly conducted at home, with three in-clinic sessions conducted over the study period of 28 days. Comparator measurements were collected from capillary samples, using a high-quality blood glucose monitoring system. RESULTS: Data from 31, 70, and 78 sensors of FBS, FL2, and ADX, respectively, were included in the performance analysis. The mean absolute relative differences between CGM and comparator data for FBS, FL2, and ADX were 14.7%, 9.2%, and 21.9%, and relative biases were -2.1%, -2.5%, and -18.5%, respectively. Analysis of individual sensor accuracy revealed low, moderate, and high sensor-to-sensor variability for FBS, FL2, and ADX, respectively. Sensor survival probabilities until the end of sensor life were 47.2% for FBS (28 days), 71.3% for FL2 (14 days), and 48.4% for ADX (14 days). CONCLUSIONS: The results of FBS were encouraging enough to conduct further performance and usability evaluations in a low- and middle-income country. The results of FL2 mainly agreed with existing studies, whereas ADX showed substantial deviations from previously reported results.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Performance Assessment of Three Continuous Glucose Monitoring Systems in Adults With Type 1 Diabetes
- Date Crossref
- 22/02/2023
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Universität Ulm pays non établi dans la noticeUniversité ou école supérieure
-
Institut für Diabetes-Technologie (Germany) pays non établi dans la noticeEntreprise
-
FIND pays non établi dans la noticeOrganisation à but non lucratif
Universität Ulm, Institut für Diabetes-Technologie (Germany) et FIND.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.