Highly Accurate and Robust Absolute Quantification of Target Proteins in Formalin-Fixed Paraffin-Embedded (FFPE) Tissues by LC–MS

3Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Accurate, absolute liquid chromatography–mass spectrometry (LC–MS)-based quantification of target proteins in formalin-fixed paraffin-embedded (FFPE) tissues would greatly expand sample availability for pharmaceutical/clinical investigations but remains challenging owing to the following issues: (i) efficient/quantitative recovery of target signature peptides from FFPE tissues is essential but an optimal procedure for targeted, absolute quantification is lacking; (ii) most FFPE samples are long-term-stored; severe immunohistochemistry (IHC) signal losses of target proteins during storage were widely reported, while the effect of storage on LC–MS-based methods was unknown; and (iii) the proper strategy to prepare calibration/quality-control samples to ensure accurate targeted protein analysis in FFPE tissues remained elusive. Using targeted quantification of monoclonal antibody (mAb), antigen, and 40 tissue markers in FFPE tissues as a model system, we extensively investigate those issues and develope an LC–MS-based strategy enabling accurate and precise targeted protein quantification in FFPE samples. First, we demonstrated a surfactant cocktail-based procedure ( f -SEPOD), providing high/reproducible recovery of target signature peptides from FFPE tissues. Second, a heat-accelerated degradation study within a roughly estimated 5 year storage period recapitulated the loss of protein IHC signals while LC–MS signals of all targets remained constant. This indicates that the storage of FFPE tissues mainly causes decreased immunoreactivity but unlikely chemical degradation of proteins, which strongly suggests that the storage of FFPE tissues does not cause significant quantitative bias for LC–MS-based methods. Third, while a conventional spike-and-extract approach for calibration caused substantial negative biases, a novel approach, using FFPE-treated calibration standards, enabled accurate and precise quantification. With the pipeline, we conducted the first-ever pharmacokinetics measurement of mAb and its target in FFPE tissues, where time courses by FFPE vs fresh tissues showed excellent correlation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Highly Accurate and Robust Absolute Quantification of Target Proteins in Formalin-Fixed Paraffin-Embedded (FFPE) Tissues by LC–MS
Date Crossref
19/12/2022
Éditeur
American Chemical Society (ACS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mass Spectrometry Techniques and ApplicationsMolecular Biology Techniques and ApplicationsAdvanced Proteomics Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.