The Poised Cannula Technique Reduces the Stereotactic Error of the Fiducial-Less Frameless DBS Procedure

2Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: In this study, we describe a technique of optimizing the accuracy of frameless deep brain stimulation (DBS) lead placement through the use of a cannula poised at the entry to predict the location of the fully inserted device. This allows real-time correction of error prior to violation of the deep gray matter. METHODS: We prospectively gathered data on radial error during the operative placements of 40 leads in 28 patients using frameless fiducial-less DBS surgery. Once the Nexframe had been aligned to target, a cannula was inserted through the center channel of the BenGun until it traversed the pial surface and a low-dose O-arm spin was obtained. Using 2 points along the length of the imaged cannula, a trajectory line was projected to target depth. If lead location could be improved, the cannula was inserted through an alternate track in the BenGun down to target depth. After intraoperative microelectrode recording and clinical assessment, another O-arm spin was obtained to compare the location of the inserted lead with the location predicted by the poised cannula. RESULTS: The poised cannula projection and the actual implant had a mean radial discrepancy of 0.75 ± 0.64 mm. The poised cannula projection identified potentially clinically significant errors (avg 2.07 ± 0.73 mm) in 33% of cases, which were reduced to a radial error of 1.33 ± 0.66 mm (p = 0.02) after correction using an alternative BenGun track. The final target to implant error for all 40 leads was 1.20 ± 0.52 mm with only 2.5% of errors being >2.5 mm. CONCLUSION: The poised cannula technique results in a reduction of large errors (>2.5 mm), resulting in a decline in these errors to 2.5% of implants as compared to 17% in our previous publication using the fiducial-less method and 4% using fiducial-based methods of DBS lead placement.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The Poised Cannula Technique Reduces the Stereotactic Error of the Fiducial-Less Frameless DBS Procedure
Date Crossref
01/01/2021
Éditeur
S. Karger AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Neurological disorders and treatmentsTranscranial Magnetic Stimulation StudiesParkinson's Disease and Spinal Disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.