Towards a versatile and economic Chagas Disease point-of-care testing system, by integrating loop-mediated isothermal amplification and contactless/label-free conductivity detection
Rattachement africain : ar, br. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Rapid diagnosis by using small, simple, and portable devices could represent one of the best strategies to limit the damage and contain the spread of viral, bacterial or protozoa diseases, principally when they can be transmitted by air and are highly contagious, as some respiratory viruses are. The presence of antibodies in blood or serum samples is not the best option for deciding when a person must be quarantined to stop transmission of disease, given that cured patients have antibodies, so the best diagnosis methods rely on the use of nucleic acid amplification procedures. Here we present a very simple device and detection principle, based on paper discs coupled to contactless conductivity (C4D) sensors, can provide fast and easy diagnostics that are needed when an epidemic outbreak develops. The paper device presented here solves one of the main drawbacks that nucleic acid amplification tests have when they are performed outside of central laboratories. As the device is sealed before amplification and integrally disposed in this way, amplimers release cannot occur, allowing repetitive testing in the physician's practice, ambulances, or other places that are not prepared to avoid cross-contamination of new samples. The use of very low volume samples allows efficient reagent use and the development of low cost, simple, and disposable point-of-care diagnostic systems.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Towards a versatile and economic Chagas Disease point-of-care testing system, by integrating loop-mediated isothermal amplification and contactless/label-free conductivity detection
- Date Crossref
- 14/05/2021
- Éditeur
- Public Library of Science (PLoS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Consejo Nacional de Investigaciones Científicas y Técnicas pays non établi dans la noticeOrganisme public
-
Instituto de Química y Fisicoquímica Biológicas pays non établi dans la noticeStructure de recherche
-
Hospital César Milstein pays non établi dans la noticeÉtablissement de santé
-
Brazilian Biosciences National Laboratory pays non établi dans la noticeStructure de recherche
-
Universidade Federal de Goiás pays non établi dans la noticeUniversité ou école supérieure
-
Biological Chemistry Department pays non établi dans la noticeInstitution
-
Science and Technology Institute Cesar Milstein (ICT-Milstein-CONICET) pays non établi dans la noticeStructure de recherche
-
Science and Technology Institute Cesar Milstein (ICT–Milstein–CONICET) pays non établi dans la noticeStructure de recherche
-
Federal University of Goiás Chemistry Institute pays non établi dans la noticeUniversité ou école supérieure
-
National Institute of Science and Technology in Bioanalytics pays non établi dans la noticeStructure de recherche
Consejo Nacional de Investigaciones Científicas y Técnicas, Instituto de Química y Fisicoquímica Biológicas et Hospital César Milstein, avec 7 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.