Extending the dynamic range of biomedical micro-computed tomography for application to geomaterials

5Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: X-ray computed tomography (CT) can non-destructively examine objects by producing three-dimensional images of their internal structure. Although the availability of biomedical micro-CT offers the increased access to scanners, CT images of dense objects are susceptible to artifacts particularly due to beam hardening. OBJECTIVE: This study proposes and evaluates a simple semi-empirical correction method for beam hardening and scatter that can be applied to biomedical scanners. METHODS: Novel calibration phantoms of varying diameters were designed and built from aluminum and poly[methyl-methacrylate]. They were imaged using two biomedical micro-CT scanners. Absorbance measurements made through different phantom sections were fit to polynomial and inversely exponential functions and used to determine linearization parameters. Corrections based on the linearization equations were applied to the projection data before reconstruction. RESULTS: Correction for beam hardening was achieved when applying both scanners with the correction methods to all test objects. Among them, applying polynomial correction method based on the aluminum phantom provided the best improvement. Correction of sample data demonstrated a high agreement of percent-volume composition of dense metallic inclusions between using the Bassikounou meteorite from the micro-CT images (13.7%) and previously published results using the petrographic thin sections (14.6% 8% metal and 6.6% troilite). CONCLUSIONS: Semi-empirical linearization of X-ray projection data with custom calibration phantoms allows accurate measurements to be obtained on the radiodense samples after applying the proposed correction method on biomedical micro-CT images.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Extending the dynamic range of biomedical micro-computed tomography for application to geomaterials
Date Crossref
01/10/2019
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced X-ray and CT ImagingMedical Imaging Techniques and ApplicationsRadiation Shielding Materials Analysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.