A paired trial comparing mononuclear cell collection in two machines for further inactivation through an inline or offline extracorporeal photopheresis procedure
Rattachement africain : es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND Extracorporeal photopheresis (ECP) is an effective treatment. However, protocols differ widely, and some questions, such as the number of cells to be collected or the number of ECP treatment days per treatment cycle, are still unsolved. The aim of this study was to compare a multistep (offline) (Spectra Optia and Macogenic G2) against an integrated (inline) ECP system (Therakos Cellex system) with respect to mononuclear cell (MNC) collection. STUDY DESIGN AND METHODS The number and quality parameters of the MNC products collected were evaluated together with some machine parameters, such as collection time. Comparisons were made through paired sample analysis with the t test. RESULTS Fourteen patients underwent 15 double‐paired procedures using both ECP protocols. The average MNC collected in the multistep procedure was 77.4 × 108, four times more than in the integrated procedure (18.5 × 108). MNC purity (84.4% vs. 63.8%) and enrichment (27.9 vs. 5.9) in the product collected were also higher in the multistep procedure. The whole ECP time was higher in the multistep than in the integrated procedure (272 vs. 106 min), but the calculated time to collect 25 × 108 MNCs in the multistep was shorter compared with the one‐step procedure (77.8 vs. 172 min). All these differences between the two protocols were statistically significant. CONCLUSIONS These two ECP protocols are different with respect to MNC collection and length of procedure. Some unresolved questions, such as the better MNC dose to inactivate or the number of consecutive days that ECP should be performed for optimal clinical efficacy, require further review.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A paired trial comparing mononuclear cell collection in two machines for further inactivation through an inline or offline extracorporeal photopheresis procedure
- Date Crossref
- 04/10/2018
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Hospital Universitario Puerta de Hierro Majadahonda Neumology Department pays non établi dans la noticeÉtablissement de santé
-
Hematology Department Hospital Universitario Puerta de Hierro‐Majadahonda Madrid Spain Therapeutic Apheresis Unit pays non établi dans la noticeÉtablissement de santé
-
Neumology Department Hospital Universitario Puerta de Hierro‐Majadahonda Madrid Spain Lung Transplant Unit pays non établi dans la noticeÉtablissement de santé
Neumology Department — Hospital Universitario Puerta de Hierro Majadahonda, Therapeutic Apheresis Unit — Hematology Department Hospital Universitario Puerta de Hierro‐Majadahonda Madrid Spain et Lung Transplant Unit — Neumology Department Hospital Universitario Puerta de Hierro‐Majadahonda Madrid Spain.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.