Aller au contenu principal
1992 article

[Clinical evaluation of 123I-BMIPP myocardial scintigraphy in patients with hypertrophic cardiomyopathy].

2Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

123I-BMIPP myocardial scintigraphy was performed in 13 patients with hypertrophic cardiomyopathy and compared with 201Tl myocardial scintigraphy performed within 3 months for evaluating the clinical significance of 123I-BMIPP myocardial scintigraphy. SPECT images were divided into 13 segments and segmental images were visually scored on a 4 (increased tracer uptake) to 0 (severely decreased tracer uptake) scale according to the tracer uptake. In comparison of 123I-BMIPP early images and 201Tl perfusion images, mismatches were seen in about 70% of all segments. The number of segments demonstrating lower myocardial uptake of 123I-BMIPP was larger than that of 201Tl. In hypertrophic regions, the tracer uptake of 123I-BMIPP early images was significantly lower than that of 201Tl images and the lower uptake of 123I-BMIPP delayed images was more marked. In non-hypertrophic regions, no significant difference was seen between the tracer uptakes of 123I-BMIPP early images and 201Tl images but the tracer uptake of 123I-BMIPP delayed images was significantly lower than that of 201Tl images. The mismatch between the tracer uptakes of 123I-BMIPP images and 201Tl images was thought to be a reflection of disordered myocardial fatty acid metabolism. "Washout", the difference between the tracer uptakes of 123I-BMIPP early images and delayed images was also thought to be a reflection of disordered myocardial fatty acid metabolism. These results suggest that 123I-BMIPP is a promising radiopharmaceutical for evaluating disordered myocardial fatty acid metabolism in patients with HCM.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Imaging Techniques and ApplicationsCardiac Imaging and DiagnosticsCancer, Hypoxia, and Metabolism

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.