Aller au contenu principal
1999 article

Influence of trapping parameters on ion injection and dissociation efficiencies in a quadrupole mass filter/ion trap tandem instrument

15Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Investigations on ion injection into a laboratory-built quadrupole/ion trap tandem instrument (Nermag R10-10/ITMS Finnigan) with a 90° geometry are described. The quadrupole dual electron impact/chemical ionization (EI/CI) source was used as an external source to prepare ions under EI (or CI) conditions. They were selected by the quadrupole analyzer and injected into the ion trap by using an electrostatic quadrupolar deflector. The effects of major trapping parameters (i.e. ion injection r.f. level and helium pressure) were considered. The injection efficiency of the stable CF3+ (m/z 69) fragment ion from FC43 and also those of the m /z 40 and 84 atomic cations of argon and krypton depend upon the injection r.f. level conditions. As expected, effects of non-linear resonances were observed during these experiments. Under certain injection and trapping conditions, ion motion can be strongly affected, yielding ion ejection, because non-linear fields (resulting from device imperfections) are present in addition to the quadrupolar potential required for ion trapping. The influences of non-linear effects according to their strength were investigated to show the best and worst trapping conditions. The non-linear resonances are characterized by the expected β z values. In order to determine the average internal energy deposited on the selected polyatomic ions during injection, butylbenzene molecular ions were chosen as a model for internal energy measurement. The effects of the r.f. injection level and helium pressure on the injected ion fragmentation were studied. The M +• ions were only observed through a narrow injection qz window. At low qz values, only low critical energy m/z 92 ions were detected, while the higher critical energy m/z 91 ions were observed at higher qz values. Copyright © 1999 John Wiley & Sons, Ltd.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Influence of trapping parameters on ion injection and dissociation efficiencies in a quadrupole mass filter/ion trap tandem instrument
Date Crossref
01/05/1999
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mass Spectrometry Techniques and ApplicationsMicrofluidic and Capillary Electrophoresis ApplicationsAnalytical chemistry methods development

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.