Unmanned Evaluation of U.S. Navy MK 11 Semi-Closed Circuit Mixed Gas UBA
Le résumé fourni par la source
NEDU performed unmanned tests on the MK 11 UBA incorporating Field Change Number 979A (modified canister configuration containing a heated central core and Koegel check valves in the M-11 mask). Breathing resistance and canister duration were evaluated at depths ranging from 250 to 750 fsw. Results showed breathing resistance to be significantly improved over previous designs and capable of supporting heavy work at depths to 650 fsw. Canister durations were improved to 450 fsw; however, most of this improvement was lost at 650 fsw in water below 40 deg F.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Unmanned Evaluation of U.S. Navy MK 11 Semi-Closed Circuit Mixed Gas UBA
- Date Crossref
- 01/06/1980
- Éditeur
- Defense Technical Information Center
- Type
- report
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.