Aller au contenu principal
Accès ouvert déclaré 2026 other

Italian Journal of Anatomy and Embryology - contenuto non piu disponibile

2Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Poly-L-lactic acid (PLLA), a hemicrystalline material, has been extensively studied in applications of engineered tissues, because it is biodegradable, absorbable and it supports cell attachment and growth. The purpose of this study is to evaluate tissue/ material interactions, neovascularization and the biocompatibility of PLLA by optical and scanning electron microscopy in a model of animal implant. PLLA porous disks were implanted into the dorsal subcutis of BALB/C mice for 1, 2, 3, and 8 weeks. The bioptic samples of excised PLLA and the surrounding tissue were evaluated for inflammatory response and tissue ingrowth. The samples were divided in two halves: one was fixed in neutral buffered formaldehyde for 24 hours, embedded in parraffin blocks, and cut into 8-μm-thick sections. The other half was fixed with 4% glutaraldehyde, dehydrated, gold coated, and was then observed with an scanning electron microscope (FEGESEM QUANTA 200 FEI). The anatomopathological examination of the implant site revealed no significant inflammatory response. The histological analysis revealed a thin fibrous capsule and a minimal inflammatory reaction with polymorphonuclear leukocytes, lymphocytes, monocytes and plasma cells around the implant, which died out during the second week. The presence of neutrophils and lymphocytes was detected until the second week after the implantation and a trama of connective tissue was found on the pores of the scaffold during the first week. The presence of giant cells was detected in the final stage of the inflammatory response and healing, which mainly occurred during the second week after the implantation. In addition, a significant angiogenic activity on the external implant surface was observed during the third week. 8 weeks after the implant, the inflammatory cell response was absolutely minimal, with an intense angiogenic activity occurring within the scaffold. This study shows the following results: PLLA has a high degree of biocompatibility and angiogenic potential; moreover, scaffolds are biocompatible in terms of cell survival and proliferation, as they stimulate a minimal inflammatory response while supporting cell infiltration, the matrix apposition and neo vascularization.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Italian Journal of Anatomy and Embryology - contenuto non piu disponibile
Date Crossref
08/07/2026
Éditeur
Firenze University Press
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

biodegradable polymer synthesis and propertiesBone Tissue Engineering MaterialsElectrospun Nanofibers in Biomedical Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.