Aller au contenu principal
2017 article

Short-term clinical outcomes for intermittent cold versus intermittent warm blood cardioplegia in 2200 adult cardiac surgery patients

10Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : at. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Aim of the present study was to compare clinical outcome of intermittent cold (ICC) versus intermittent warm (IWC) blood cardioplegia in different cardiosurgical procedures. METHODS: Two thousand one hundred and eighty-eight patients were retrospectively divided into 5 groups: isolated coronary artery bypass surgery (CABG; N.=1203), isolated aortic valve surgery (AVR; N.=374), isolated mitral valve surgery (MVR; N.=151), combined AVR+CABG (N.=390), and combined MVR+CABG (N.=70). Myocardial protection was performed by ICC (N.=1578) or IWC (N.=610) blood cardioplegia. In logistic regression models the effect of cardioplegia on 30-day mortality, IABP/ECLS (intraaortic balloon-pump/extracorporal life support) implantation, transient neurological deficit, stroke, renal failure, new-onset atrial fibrillation, and troponin T release was estimated. Potential modifications of the effect of cardioplegia by logistic EuroSCORE, cross-clamping time, ejection fraction, and op-status elective versus urgent/emergent were investigated. RESULTS: There were no statistically significant differences between ICC and IWC regarding 30-day mortality (odds ratio [OR]=0.70; 95% CI: 0.39-1.23; P=0.219), IABP/ECLS support (OR=0.60; 95% CI: 0.23-1.55; P=0.294), transient neurological deficit (OR=0.90; 95% CI: 0.65-1.24; P=0.541), stroke (OR=0.79; 95% CI: 0.40-1.54; P=0.495), renal failure (OR=1.07; 95% CI: 0.57-1.99; P=0.825), and atrial fibrillation (OR=0.96; 95% CI: 0.77-1.18; P=0.713) across all 5 groups. Troponin t release was significantly higher in ICC compared to IWC (by 0.029±0.015 ng/mL; P=0.046) in univariate analysis; this effect was lowered by risk-factor adjustment and lost statistical significance. The effect of cardioplegia was not significantly different between groups. In urgent/emergent surgery ICC resulted in a significantly higher 30-day mortality (OR=3.03; P=0.024) compared to IWC. CONCLUSIONS: The comparison of IWC and ICC blood cardioplegia in different cardiosurgical procedures showed no statistical significant difference in myocardial protection. The use of ICC, however, appeared overall associated with a slightly better clinical outcome except in patients undergoing urgent/emergent CABG where IWC led to a reduction in 30-day-mortality.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Short-term clinical outcomes for intermittent cold versus intermittent warm blood cardioplegia in 2200 adult cardiac surgery patients
Date Crossref
01/01/2017
Éditeur
Edizioni Minerva Medica
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Ischemia and ReperfusionCardiac and Coronary Surgery TechniquesCardiac Arrest and Resuscitation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.