Aller au contenu principal
2002 article

Closed, Phosphorylcholine-Coated Circuit and Reduction of Systemic Heparinization for Cardiopulmonary Bypass: The Intraoperative ECMO Concept

36Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Cardiopulmonary bypass with heparin-bonded circuits reduces systemic heparinization which is associated to a better clinical outcome in cardiac operations. In the present study, a novel biocompatible treatment, based on a phosphorylcholine coating without heparin, has been used to reduce systemic heparinization during cardiopulmonary bypass. Sixty patients underwent coronary revascularization with a fully phosphorylcholine-coated circuit. The circuit was entirely closed; suctions from the field were separated during the cardiopulmonary bypass time. A low systemic heparinization protocol based on half the loading dose of heparin (150 IU/kg) and a target activated clotting time of 320 seconds was applied. No thrombus formation inside the extracorporeal circulation circuit occurred; in-hospital mortality was absent. One patient (1.6%) had a postoperative myocardial infarction and 2 (3.3%) were surgically revised due to bleeding. Homologous blood transfusion rate was 11.6%, postoperative bleeding was 310 +/- 136 ml. If compared to patients treated with heparin-coated circuits and low systemic heparinization, these patients have better platelet count preservation and lower postoperative bleeding. The low thrombogenicity of phosphorylcholine-treated surfaces, despite the absence of surface-immobilized heparin, allows a safe reduction of systemic heparinization in the setting of an ECMO-like intraoperative cardiopulmonary - bypass. This intraoperative ECMO approach offers promising results in terms of clinical outcome after coronary revascularization operations.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Closed, Phosphorylcholine-Coated Circuit and Reduction of Systemic Heparinization for Cardiopulmonary Bypass: The Intraoperative ECMO Concept
Date Crossref
01/09/2002
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac and Coronary Surgery TechniquesCardiac Valve Diseases and TreatmentsMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.