Accès ouvert
2018
article
OpenAlex
T. Aaltonen, V. M. Abazov, B. Abbott, B. S. Acharya et autres
The CDF and D0 experiments at the Fermilab Tevatron have measured the asymmetry between yields of forward- and backward-produced top and antitop quarks based on their rapidity difference and the asymmetry between their decay leptons. These measurements use the full data sets …
fi, ru, us, in, gb, it, sk, jp, cz, ua, co, fr, kr, br, de
(code pays fourni par la source)
2002
article
OpenAlex
V. M. Abazov, D. A. Stoyanova, J. Warchol, O. V. Eroshin et autres
1996
article
OpenAlex
A. Airapetian, Fred Olness, V. Dodonov, L. Micu et autres
Accès ouvert
1991
conference-paper
OpenAlex
Michael G. Strauss, Edwin M. Westbrook, Istvan Naday, Tom A. Coleman et autres
A detector with a 114 mm aperture, based on a charge-coupled device (CCD), has been designed for x-ray diffraction studies in protein crystallography. The detector was tested on a beamline of the National Synchrotron Light Source at Brookhaven National Laboratory with a …
us
(code pays fourni par la source)
1991
article
OpenAlex
Michael G. Strauss, E.M. Westbrook, Istvan Naday, Tom A. Coleman et autres
1989
article
OpenAlex
Nestor J. Zaluzec, Michael G. Strauss
us
(code pays fourni par la source)
Accès ouvert
1987
article
OpenAlex
H. Aihara, Margaret Alston-Garnjost, R. E. Avery, J. A. Bakken et autres
We have measured the branching ratios for several \ensuremath{\tau} decay modes. We use ${e}^{+}$${e}^{\mathrm{\ensuremath{-}}}$\ensuremath{\rightarrow}${\ensuremath{\tau}}^{+}$${\ensuremath{\tau}}^{\mathrm{\ensuremath{-}}}$ events accumulated with the TPC/Two-Gamma facility at the SLAC ${e}^{+}$${e}^{\mathrm{\ensuremath{-}}}$ storage ring PEP. The data correspond to an integrated luminosity of 77 ${\mathrm{pb}}^{\mathrm{\ensuremath{-}}1}$ at a center-of-mass energy of …
fr, es, de, tw, ch, gb
(code pays fourni par la source)
Accès ouvert
1987
conference-paper
OpenAlex
Michael G. Strauss, Istvan Naday, Irvin S. Sherman, Martin R. Kraimer et autres
The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron x-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction …
1987
article
OpenAlex
Michael G. Strauss, Istvan Naday, Irvin S. Sherman, Nestor J. Zaluzec
us
(code pays fourni par la source)
Accès ouvert
1986
article
OpenAlex
Richard H. Pehl, Norman W. Madden, John T. Walton, Don F. Malone et autres
us
(code pays fourni par la source)
1986
article
OpenAlex
Michael G. Strauss, Irvin S. Sherman, C.T. Roche, Richard H. Pehl
us
(code pays fourni par la source)
Accès ouvert
1986
conference-paper
OpenAlex
Michael G. Strauss, Istvan Naday, Irvin S. Sherman, Martin R. Kraimer et autres
The intense x radiation from a synchrotron source could, with a suitable detector, provide a complete set of diffraction images from a protein crystal before the crystal is damaged by radiation (2 to 3 min). An area detector consisting of a 40 …
us
(code pays fourni par la source)