Accès ouvert
2016
report
OpenAlex
Argonne National Lab. (ANL), Argonne, IL (United States), D. Kultgen, USDOE Office of Nuclear Energy (NE), C. Grandy et autres
This report documents the current status of the Mechanisms Engineering Test Loop (METL) as of the end of FY2016. Currently, METL is in Phase I of its design and construction. Once operational, the METL facility will test small to intermediate-scale components and …
us
(code pays fourni par la source)
Accès ouvert
2012
article
OpenAlex
Peter N. Ostroumov, B. Mustapha, A. Barcikowski, C. Dickerson et autres
The front end of any modern ion accelerator includes a radio frequency quadrupole (RFQ). While many pulsed ion linacs successfully operate RFQs, several ion accelerators worldwide have significant difficulties operating continuous wave (CW) RFQs to design specifications. In this paper we describe …
us
(code pays fourni par la source)
Accès ouvert
2012
article
OpenAlex
W. Toter, L. Ristori
In order to reduce the sensitivity of the Fermilab SSR1 resonator to helium pressure variations, it was concluded that the cavity and helium vessel end-walls needed to be structurally coupled by means of a transition ring. With the materials t o be …
us
(code pays fourni par la source)
2007
article
OpenAlex
D. Schrage, Peter N. Ostroumov, A. Barcikowski, M. Bracken et autres
2006
article
OpenAlex
Peter N. Ostroumov, A. Barcikowski, B.E. Clifft, B. Rusthoven et autres
High power heavy-ion drivers require a CW low-frequency RFQ for initial acceleration. The low frequency specifications required for heavy-ion acceleration typically result in large dimensions of the structure. By appropriate choice of the resonant structure for the Rare Isotope Accelerator (RIA) driver …
2003
article
OpenAlex
J. D. Fuerst, W. Toter, Kenneth W. Shepard
We present results of an R&D program to develop and test a reliable cryogenic leak-tight, copper-brazed transition between niobium and stainless steel for use in superconducting niobium cavities. We have chosen to make the integral helium container that houses a niobium cavity …
Accès ouvert
2002
conference-paper
OpenAlex
M. Jaski, K. Thompson, Sang On Kim, Horst W. Friedsam et autres
The design, construction, and installation of pulsed septum magnets for particle accelerators presents many challenges for the magnet engineer. Issues associated with magnet core structure design, component alignment, weldment design, and electrical insulation choices are among those requiring careful attention. The designs …
us
(code pays fourni par la source)