Jahn Frederik Grue, Sigurd Storve, Håvard Dalen, Ole Christian Mjølstad et autres
BACKGROUND: Automatic analyses of echocardiograms may support inexperienced users in quantifying left ventricular (LV) function. We have developed an algorithm for fully automatic measurements of mitral annular plane systolic excursion (MAPSE) and mitral annular systolic (S') and early diastolic (e') peak velocities. …
no
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Jahn Frederik Grue, Sigurd Storve, Asbjørn Støylen, Hans Garmann Torp et autres
BACKGROUND: Automatic quantification of left ventricular (LV) function could enhance workflow for cardiologists and assist inexperienced clinicians who perform focused cardiac ultrasound. We have developed an algorithm for automatic measurements of the mitral annular plane systolic excursion (MAPSE) and peak velocities in …
no
(code pays fourni par la source)
Accès ouvert
2019
paratext
OpenAlex
Jahn Frederik Grue, Sigurd Storve, Asbjørn Støylen, Hans Garmann Torp et autres
The front cover image is based on the Original Article Normal ranges for automatic measurements of tissue Doppler indices of mitral annular motion by echocardiography. Data from the HUNT3 Study by Jahn Frederik Grue et al., https://doi.org/10.1111/echo.14476.
Accès ouvert
2018
article
OpenAlex
Jahn Frederik Grue, Sigurd Storve, Hans Garmann Torp, Ole Christian Mjølstad et autres
Background: Tissue Doppler imaging is widely used to quantify global left ventricular (LV) longitudinal function. We have developed an algorithm that automatically measures the mitral annular peak velocities in systole (S'), early diastole (e') and late diastole (a'). This algorithm can be …
no
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Jahn Frederik Grue, Sigurd Storve, Håvard Dalen, Øyvind Olav Salvesen et autres
The purpose of the study described here was to evaluate an automatic algorithm for detection of left ventricular dysfunction, based on measurements of mitral annular motion indices from color tissue Doppler apical four-chamber recordings. Two hundred twenty-one patients, among whom 49 had …
no
(code pays fourni par la source)
2017
article
OpenAlex
Jahn Frederik Grue, Sigurd Storve, Ole Christian Mjølstad, Øyvind Olav Salvesen et autres
Introduction: With the increasing use of pocket-sized ultrasound devices by inexperienced users, automated measurements of left ventricular (LV) function will represent an advantage. LV longitudinal function is reduced in patients with systolic and diastolic dysfunction, and can be quantified by measuring the …
no
(code pays fourni par la source)
2017
article
OpenAlex
Sigurd Storve, Hans Garmann Torp
Simulated ultrasound data is a valuable tool for development and validation of quantitative image analysis methods in echocardiography. Unfortunately, simulation time can become prohibitive for phantoms consisting of a large number of point scatterers. The COLE algorithm by Gao et al. is …
no
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Naiad Hossain Khan, Eva Tegnander, Sigurd Storve, Johan Morten Dreier et autres
An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, the location of fetal abdomen is detected by image processing. Thereafter, …
no, it
(code pays fourni par la source)
2016
article
OpenAlex
Sigurd Storve, Jahn Frederik Grue, Stein Olav Samstad, Håvard Dalen et autres
Assessment of cardiac function by echocardiography is challenging for nonexperts. In a patient with dyspnea, quantification of the mitral annular excursion (MAE) and velocities is important for the diagnosis of heart failure. The displacement of the atrioventricular (AV) plane is a good …
no
(code pays fourni par la source)
2015
conference-paper
OpenAlex
Sigurd Storve, Hans Garmann Torp
Synthetic ultrasound data is invaluable for applications such as tuning image segmentation algorithms. Unfortunately, simulation time can become prohibitive for phantoms consisting of a large number of point-scatterers. In such cases, simplified simulation algorithms can be useful, and trade accuracy for speed. …
no
(code pays fourni par la source)
2014
conference-paper
OpenAlex
Sigurd Storve, Jahn Frederik Grue, Stein Olav Samstad, Håvard Dalen et autres
Assessment of heart function by echocardiography is challenging for non-experts. In a patient with dyspnea, assessment of mitral annular excursion (MAE) and velocities are important for the diagnosis of heart failure. By automatic measurement of these parameters, a preliminary diagnosis could be …
no
(code pays fourni par la source)
2014
conference-paper
OpenAlex
Gabriel Hanssen Kiss, Sigurd Storve, Bjørn Olav Haugen, Hans Garmann Torp
It is envisioned that tablet based ultrasound systems will be targeting non-expert users in the near future. However ultrasound is operator dependent and requires an extensive training process. The aim of this work is to provide visual guidance during scanning and as …