Accès ouvert
2024
article
OpenAlex
Steven R. Sarkisian, Robert Edward T. Ang, Andy M. Lee, John Palmer Berdahl et autres
us, ph
(code pays fourni par la source)
Accès ouvert
2024
book-chapter
OpenAlex
Farrell C. Tyson, Stefan Pieger, Harkaran S. Bains
Abstract The OPD-Scan III is a multiple-instrument device combining corneal topography, wavefront aberrometry, autorefraction, keratometry, pupillometry, and pupillography. The measurement of topography and whole eye wavefront allows separation of corneal and internal aberrations for rapid assessment of the refractive and optical effects …
Accès ouvert
2023
article
OpenAlex
John Palmer Berdahl, Steven R. Sarkisian, Robert Edward T. Ang, Long V. Doan et autres
PURPOSE: A randomized, double-masked, multicenter, phase 2 trial to evaluate the long-term safety and efficacy of travoprost intraocular implant, an extended-release drug delivery system designed to provide uninterrupted sustained intraocular pressure (IOP)-lowering therapy, thereby reducing patient treatment burden and improving adherence with …
us, ph
(code pays fourni par la source)
Accès ouvert
2021
article
OpenAlex
Jason Bacharach, Andrew J. Tatham, Gloria E. Ferguson, Sandra Belalcázar et autres
OBJECTIVE: To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS: This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG …
us, gb, co, de
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Sanjay Asrani, Alan Lee Robin, Janet B. Serle, Richard Alan Lewis et autres
PURPOSE: To compare the ocular hypotensive efficacy and safety of a fixed-dose combination (FDC) of the Rho kinase inhibitor netarsudil and latanoprost vs monotherapy with netarsudil or latanoprost. DESIGN: Three-month primary endpoint analysis of a randomized, double-masked, phase 3 clinical trial. METHODS: …
us
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Thomas W. Samuelson, David M. Lubeck, Yi-Jing Duh, Eeke A. Romo et autres
PURPOSE: Evaluate the safety and effectiveness of an ab interno implanted (iStent inject) Trabecular Micro-Bypass System (Glaukos Corporation, San Clemente, CA) in combination with cataract surgery in subjects with mild to moderate primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, single-masked, concurrently controlled, …
us
(code pays fourni par la source)
2015
article
OpenAlex
Marrie van der Mooren, Roger F. Steinert, Farrell C. Tyson, Michelle J.M. Langeslag et autres
UNLABELLED: We report 2 cases in which single-piece multifocal acrylic intraocular lenses (IOLs) were explanted because of complications related to the presence of glistenings in the bulk of the IOL optic. In both cases, the patients complained about blurry or hazy vision. …
de, us
(code pays fourni par la source)
2014
article
OpenAlex
Samuel Masket, John A. Hovanesian, Jeffrey Levenson, Farrell C. Tyson et autres
PURPOSE: To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. SETTING: Twenty-four ophthalmic clinical practices in the United States. DESIGN: Prospective randomized parallel-arm controlled multicenter subject-masked study. METHODS: Healthy patients …
fr, us
(code pays fourni par la source)
Accès ouvert
2013
article
OpenAlex
Farrell C. Tyson, Mitchell A. Jackson, Jonathan Solomon
Following advances in intraocular lens technology in recent years, greatly increased options are now available to the ophthalmic surgeon. However, there is a need for improved diagnostic technologies to optimize outcomes and select the best treatment strategies. A process combining multimodal wavefront …
us
(code pays fourni par la source)
1993
article
OpenAlex
Wallace Chamon, Yonca A. Akova, Farrell C. Tyson, Dimitri T. Azar et autres
Chamon, Wallace M.D.; Akova, Yonca A. M.D.; Tyson, Farrell C.; Azar, Dimitri T. M.D.; Stark, Walter J. M.D.