Aller au contenu principal
Profil bibliographique

Farrell C. Tyson

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

10Publications signalées
632Citations signalées
0Affiliations récentes

Les domaines associés

Glaucoma and retinal disordersIntraocular Surgery and LensesRetinal and Macular SurgeryOphthalmology and Visual Impairment StudiesCorneal surgery and disorders

Les publications récentes

Accès ouvert 2024 book-chapter OpenAlex

The NIDEK Cataract Suite: The OPD-Scan III Multifunction Diagnostic Device and the AL-Scan Optical Biometer

Farrell C. Tyson, Stefan Pieger, Harkaran S. Bains

Abstract The OPD-Scan III is a multiple-instrument device combining corneal topography, wavefront aberrometry, autorefraction, keratometry, pupillometry, and pupillography. The measurement of topography and whole eye wavefront allows separation of corneal and internal aberrations for rapid assessment of the refractive and optical effects …

0 citations Essentials in ophthalmology/Essentials ophthalmology
Accès ouvert 2023 article OpenAlex

Efficacy and Safety of the Travoprost Intraocular Implant in Reducing Topical IOP-Lowering Medication Burden in Patients with Open-Angle Glaucoma or Ocular Hypertension

John Palmer Berdahl, Steven R. Sarkisian, Robert Edward T. Ang, Long V. Doan et autres

PURPOSE: A randomized, double-masked, multicenter, phase 2 trial to evaluate the long-term safety and efficacy of travoprost intraocular implant, an extended-release drug delivery system designed to provide uninterrupted sustained intraocular pressure (IOP)-lowering therapy, thereby reducing patient treatment burden and improving adherence with …

us, ph (code pays fourni par la source)

40 citations Drugs
Accès ouvert 2021 article OpenAlex

Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2)

Jason Bacharach, Andrew J. Tatham, Gloria E. Ferguson, Sandra Belalcázar et autres

OBJECTIVE: To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). METHODS: This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG …

us, gb, co, de (code pays fourni par la source)

75 citations Drugs
Accès ouvert 2019 article OpenAlex

Netarsudil/Latanoprost Fixed-Dose Combination for Elevated Intraocular Pressure: Three-Month Data from a Randomized Phase 3 Trial

Sanjay Asrani, Alan Lee Robin, Janet B. Serle, Richard Alan Lewis et autres

PURPOSE: To compare the ocular hypotensive efficacy and safety of a fixed-dose combination (FDC) of the Rho kinase inhibitor netarsudil and latanoprost vs monotherapy with netarsudil or latanoprost. DESIGN: Three-month primary endpoint analysis of a randomized, double-masked, phase 3 clinical trial. METHODS: …

us (code pays fourni par la source)

84 citations American Journal of Ophthalmology
Accès ouvert 2019 article OpenAlex

Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract

Thomas W. Samuelson, David M. Lubeck, Yi-Jing Duh, Eeke A. Romo et autres

PURPOSE: Evaluate the safety and effectiveness of an ab interno implanted (iStent inject) Trabecular Micro-Bypass System (Glaukos Corporation, San Clemente, CA) in combination with cataract surgery in subjects with mild to moderate primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, single-masked, concurrently controlled, …

us (code pays fourni par la source)

306 citations Ophthalmology
2015 article OpenAlex

Explanted multifocal intraocular lenses

Marrie van der Mooren, Roger F. Steinert, Farrell C. Tyson, Michelle J.M. Langeslag et autres

UNLABELLED: We report 2 cases in which single-piece multifocal acrylic intraocular lenses (IOLs) were explanted because of complications related to the presence of glistenings in the bulk of the IOL optic. In both cases, the patients complained about blurry or hazy vision. …

de, us (code pays fourni par la source)

28 citations Journal of Cataract & Refractive Surgery
2014 article OpenAlex

Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery

Samuel Masket, John A. Hovanesian, Jeffrey Levenson, Farrell C. Tyson et autres

PURPOSE: To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. SETTING: Twenty-four ophthalmic clinical practices in the United States. DESIGN: Prospective randomized parallel-arm controlled multicenter subject-masked study. METHODS: Healthy patients …

fr, us (code pays fourni par la source)

75 citations Journal of Cataract & Refractive Surgery
Accès ouvert 2013 article OpenAlex

Combining Multimodal Wavefront Examination and Digital Refraction to Create a Rapid and Accurate Approach (XFraction) for a Total Visual System Assessment for Intraocular Lens Selection

Farrell C. Tyson, Mitchell A. Jackson, Jonathan Solomon

Following advances in intraocular lens technology in recent years, greatly increased options are now available to the ophthalmic surgeon. However, there is a need for improved diagnostic technologies to optimize outcomes and select the best treatment strategies. A process combining multimodal wavefront …

us (code pays fourni par la source)

0 citations touchREVIEWS in Ophthalmology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.