2008
article
OpenAlex
Francisco Maduell, A. Caridad, Florencio Sigüenza, F Miralles et autres
Since the urea kinetic model is used as an objective method for monitoring dialysis, it has been possible to shorten reasonably its duration. From the usual practice, we have observed that it is easier to reduce the dialysis time in women as …
es
(code pays fourni par la source)
Accès ouvert
2008
book-review
OpenAlex
Francisco Maduell, A. Caridad, Florencio Sigüenza, Frank Miralles et autres
2008
article
OpenAlex
Francisco Maduell, Florencio Sigüenza, A. Caridad, F Miralles et autres
According to the urea kinetic model it is considered that the urea distribution volume (V) is that of body water, and that it is distributed in only one compartment. Since the V value is different to measure, it is normal to use …
es
(code pays fourni par la source)
2008
book-review
OpenAlex
Raymond Ardaillou, Jean‐Claude Dussaule, Mitchell Lewis Halperin, Surinder Cheema‐Dhadli et autres
2008
article
OpenAlex
Enric Grau, Florencio Sigüenza, Francisco Maduell, Mariano Linares et autres
In 14 patients undergoing chronic hemodialysis, we investigated the safety and efficacy of the low molecular fragment (CY-216) in comparison to unfractionated heparin (UFH) in the prevention of clotting in the extracorporeal circuit (ECC). In this study, 168 hemodialysis sessions were undertaken …
us, es
(code pays fourni par la source)
2008
erratum
OpenAlex
Joaquín Ortuño, Luis A. Jiménez del Cerro, Francisco Rivera Hernández, Vijay Kher et autres
1998
article
OpenAlex
Ramón López-Menchero, Florencio Sigüenza, A. Caridad, Juan Carlos Gómez Alonso et autres
1998
article
OpenAlex
Francisco Maduell, Juan‐Carlos García‐Valdecasas, Hortensia Cepa García, J. Hdez-Jaras et autres
An American National Study shows that survival benefits from higher dialysis doses appear to be present up to a Kt/V level of 1.3 or a urea reduction ratio (URR) of 70%. The effect of increasing dialysis efficiency magnified urea rebound and the …
es
(code pays fourni par la source)
Accès ouvert
1997
article
OpenAlex
Francisco Maduell, Juan‐Carlos García‐Valdecasas, Hortensia Cepa García, J. Hdez-Jaras et autres
BACKGROUND: The effect of increasing dialysis efficiency magnifies rebound urea and the error in Kt/V determinations from single pool urea kinetics. Several formulae have been developed to calculate Kt/V taking into account the rebound urea (Kt/Vr). Smye et al. proposed a method …
es
(code pays fourni par la source)
1995
article
OpenAlex
Florencio Sigüenza, Francisco Maduell, Matïlde Perella, R. Lopez-Manchero et autres
F. Sigüenza, F. Maduell, M. Perella, R. Lopez-Manchero, E. Grau, E. Pastor; Low molecular weight heparin (‘fragmin’) in haemodialysis: is laboratory monitoring
es
(code pays fourni par la source)
1993
article
OpenAlex
Francisco Maduell, Agustín Sánchez-Alcaraz, Florencio Sigüenza, A. Caridad et autres
Recent reports suggest that cyclosporin A is beneficial in inducing remission of idiopathic nephrotic syndrome. Nephrotic syndrome is seen in 10-30% of patients with rapidly progressive glomerulonephritis. We report a case of a 69-year-old man with nephrotic syndrome, associated with idiopathic rapidly …
es
(code pays fourni par la source)