Accès ouvert
2026
conference-paper
OpenAlex
Jyh-Chyuan Jan, Yang-Yang Hsu, Yun-Liang Chu, Chih‐Sheng Yang et autres
Integrating permanent magnets as substitutes for large electromagnets offers advantages such as energy savings, space efficiency, and low maintenance. An electromagnetic dipole magnet on the TPS transfer line is proposed to be replaced by a permanent magnet. This permanent magnet will be …
Accès ouvert
2026
conference-paper
OpenAlex
Chih‐Sheng Yang, Chin-Kang Yang, F. Y. Lin, Yun-Liang Chu et autres
The Taiwan Photon Source (TPS) storage ring employs a traditional four-kicker bump off-axis injection scheme, which can introduce perturbations to the stored beam during the injection phase. To address these issues and facilitate stable top-up injection, a Nonlinear In-vacuum Kicker (NIK) has …
2025
conference-paper
OpenAlex
Y. H. Chen, Y. S. Chen, Y. C. Ong, Yun-Liang Chu et autres
Magnetic random-access memory (MRAM) shows great promise as an embedded working memory solution for data-intensive high-performance computing (HPC) and artificial intelligence (AI) applications. It requires not only high speed but also exceptional endurance performance. In this study, we discovered that current impact …
tw
(code pays fourni par la source)
2024
article
OpenAlex
Chih‐Wei Chen, Chung-Ting Chang, Hsiung Chen, Yun-Liang Chu et autres
The adjustable strength permanent magnet quadrupoles used in this study were designed and manufactured at the National Synchrotron Radiation Research Center (NSRRC). The permanent magnet quadrupole had a bore radius of 3.5 mm and an effective length of 50 mm. It was …
tw
(code pays fourni par la source)
Accès ouvert
2022
conference-paper
OpenAlex
Ting-Yi Chung, Huihuang Chen, Yun-Liang Chu, Hsiung Chen et autres
Abstract An undulator composed of an electromagnet (EM) and a permanent magnet (PM) has been developed to switch rapidly the right- or left-circularly polarized radiation. The polarization switching is achieved using the rapid change of polarity of excitation currents in the EM, …
tw
(code pays fourni par la source)
2022
article
OpenAlex
Jhao-Cyuan Huang, Yongseng Wong, Kuo-Bin Liu, Jyh-Chyuan Jan et autres
Abstract This work describes the integration of a high precision power supply in a scan magnet in National Synchrotron Radiation Research Center (NSRRC). Horizontal and vertical energy transmission to the scan magnet are independent. The high precision and sinewave are utilised to …
tw
(code pays fourni par la source)
2022
article
OpenAlex
Chih‐Wei Chen, Yang-Yang Hsu, Yun-Liang Chu, Hsiung Chen et autres
A cryogenic permanent-magnet undulator (CPMU) with period 18 mm and magnetic length 2 m is being constructed for Taiwan Photon Source. The CPMU (gap 5.5 mm) can generate effective magnetic field 1.18 T at magnetic arrays temperature of 170K. When the field …
tw
(code pays fourni par la source)
Accès ouvert
2021
article
OpenAlex
Che-Kai Chan, Chin-Chun Chang, Ho-Ping Chang, Yung-Sen Cheng et autres
Feasibility of applying MIK/sextupole injection at TPS is evaluated in this study. This study adopts layout similar to MAX IV injection scheme and their collaboration project with SOLEIL for MIK. Although the light source service fulfills present user needs, yet the increasing …
tw, us
(code pays fourni par la source)
Accès ouvert
2020
article
OpenAlex
Jui-Che Huang, Yongseng Wong, K.-B. Liu, C.-Y. Liu et autres
Taiwan Photon Source (TPS) has been operated for 6 years, and the mean time between fails has reached world-class standards since the first light was delivered on 31 December 2013. To maintain satisfactory research facilities, all subsystems are constantly updating their equipment. …
tw
(code pays fourni par la source)
2019
article
OpenAlex
Chin-Kang Yang, Jui-Che Huang, Chih‐Sheng Yang, Chih‐Wei Chen et autres
A PrFeB-based cryogenic permanent-magnet undulator (CPMU) with a period length of 15 mm (CU15) is being constructed to provide high brilliant X-rays for the Taiwan Photon Source (TPS) nano-probe beamline. Field measurements of this undulator will be performed with a Hall probe …
tw
(code pays fourni par la source)
2018
article
OpenAlex
Yun-Liang Chu, Ting-Yi Chung, Chih‐Sheng Yang, Chin-Kang Yang et autres
To measure the magnetic fields with a Hall probe, accurate alignment needs to be considered. Therefore, we present improvements to the Hall probe measurement system, including cone magnets and a zero-field shield as simulated by the OPERA. The design of the cone …
tw
(code pays fourni par la source)
2018
article
OpenAlex
Chin-Kang Yang, Wen‐Hsuan Hsieh, Yun-Liang Chu, C. H. Chang et autres
A cryogenic permanent-magnet undulator (CPMU) with a 15-mm period length is being constructed for the TPS. Field measurements of this undulator will be performed with a Hall probe at cryogenic temperatures, for which a field strength and temperature-dependent calibration system is necessary. …
tw
(code pays fourni par la source)