Aller au contenu principal
Profil bibliographique

Sylvie Pierre

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

61Publications signalées
518Citations signalées
4Affiliations récentes

Les institutions déclarées

Les domaines associés

Radioactivity and Radon MeasurementsNuclear Physics and ApplicationsRadioactive Decay and Measurement TechniquesRadiation Detection and Scintillator TechnologiesRadioactive contamination and transfer

Les publications récentes

Accès ouvert 2026 other OpenAlex

RadonNET Workshop Low-Cost Sensors and Calibration - Session I

Annette Röttger, Benoit SABOT, Stefan Röttger, Katarzyna Wołoszczuk et autres

This workshop was conducted within the RadonNET project, co-organised by the IMEKO. RadonNET aims to eliminate preventable lung cancer cases caused by the radioactive noble gas radon (222Rn) and its progeny. Through the development of advanced sensor networks and calibration techniques, the …

de, fr, pl, bg, lv, au, es (code pays fourni par la source)

0 citations Zenodo (CERN European Organization for Nuclear Research)
Accès ouvert 2026 other OpenAlex

RadonNET Workshop Low-Cost Sensors and Calibration - Session I

Annette Röttger, Benoit SABOT, Stefan Röttger, Katarzyna Wołoszczuk et autres

This workshop was conducted within the RadonNET project, co-organised by the IMEKO. RadonNET aims to eliminate preventable lung cancer cases caused by the radioactive noble gas radon (222Rn) and its progeny. Through the development of advanced sensor networks and calibration techniques, the …

de, fr, pl, bg, lv, au, es (code pays fourni par la source)

0 citations Zenodo (CERN European Organization for Nuclear Research)
Accès ouvert 2026 other OpenAlex

RadonNET Workshop Low-Cost Sensors and Calibration - Session II

Stefan Röttger, Krasimir K. Mitev, Ivelina Dimitrova, Benoit SABOT et autres

This workshop was conducted within the RadonNET project, co-organised by the IMEKO. RadonNET aims to eliminate preventable lung cancer cases caused by the radioactive noble gas radon (222Rn) and its progeny. Through the development of advanced sensor networks and calibration techniques, the …

de, fr, bg, gb, fi (code pays fourni par la source)

0 citations Zenodo (CERN European Organization for Nuclear Research)
Accès ouvert 2026 other OpenAlex

RadonNET Workshop Low-Cost Sensors and Calibration - Session II

Stefan Röttger, Krasimir K. Mitev, Ivelina Dimitrova, Benoit SABOT et autres

This workshop was conducted within the RadonNET project, co-organised by the IMEKO. RadonNET aims to eliminate preventable lung cancer cases caused by the radioactive noble gas radon (222Rn) and its progeny. Through the development of advanced sensor networks and calibration techniques, the …

de, fr, bg, gb, fi (code pays fourni par la source)

0 citations Zenodo (CERN European Organization for Nuclear Research)
Accès ouvert 2026 article OpenAlex

241 Am : A new nuclide for reference α − filter production and calibration

Grégoire Dougniaux, Benoît Sabot, Bernadette Dhieux Lestaevel, Sylvie Pierre

In the field of nuclear safety and environmental monitoring, accurate measurement of radionuclide activity in aerosols collected on filters is of critical importance, particularly in terms of the traceability of such measurements, as they can inform operational decision-making. Laboratories, especially in France, …

fr (code pays fourni par la source)

0 citations Applied Radiation and Isotopes
Accès ouvert 2025 article OpenAlex

First intercomparison of 241Am activity measurements using primary methods including magnetic micro-calorimetrers

Matias Rodrigues, Quentin Drenne, F. Juget, Miguel Roteta et autres

Low-temperature detectors, such as Magnetic Micro-calorimeters (MMCs), exhibit several characteristics that make them strong candidates for primary activity standardization of various radionuclides. As a relatively new technique, however, many aspects of MMC-based measurements still require validation. For this purpose, 241 Am was …

fr, ch, es, de (code pays fourni par la source)

0 citations Applied Radiation and Isotopes
Accès ouvert 2025 article OpenAlex

On the techniques for primary calibration of electronic radon detectors

Krasimir K. Mitev, Benoît Sabot, Vladislav Todorov, Strahil B. Georgiev et autres

Successful calibration of RadonEye +2 electronic radon detectors was performed at typical indoor activity concentrations using the facilities at LNHB and PTB. The calibration uncertainties using primary radon activity standards were: below 1.5 % at 300 Bq/m 3 , below 1.7 % …

bg, fr, de (code pays fourni par la source)

0 citations Applied Radiation and Isotopes
Accès ouvert 2025 article OpenAlex

Production of radioactive traceable reference materials for measuring radioactive pollutants in the environment

Lucille Chambon, Hélène Isnard, Sylvie Pierre, Benoît Sabot et autres

There are very few radioactive environmental reference materials (RM) traceable to the International System of Units. Existing radioactive RMs for environmental samples that can be measured by mass spectrometry are even more limited and their characterisation does not always include relevant parameters …

fr, de, ch, cz, dk, gb (code pays fourni par la source)

0 citations Applied Radiation and Isotopes
Accès ouvert 2025 article OpenAlex

Activity standardization and determination of nuclear decay data of 212Pb at LNE-LNHB and first measurements in the SIR at BIPM

C. Bobin, Marie-Noëlle Amiot, Carine Michotte, B. H. Boyer et autres

Lead-212/Bismuth-212 is a promising radiopharmaceutical with high therapeutic potential for Targeted Alpha Therapy. In this paper, the activity standardization of 212 Pb in equilibrium with its progeny was addressed by means of several measurement techniques at LNE-LNHB using a radioactive solution of …

fr (code pays fourni par la source)

1 citation Applied Radiation and Isotopes
Accès ouvert 2025 article OpenAlex

Development of a radon-in-water primary standard

Benoît Sabot, P. Cassette, Marie‐Christine Lépy, Sylvie Pierre et autres

Abstract The absence of a certified standard for radon-in-water presents a significant gap in environmental monitoring and water production quality control in compliance with EURATOM directive 2013/51. To address this, we developed a system to produce a radon-in-water primary standard derived from …

fr, bg (code pays fourni par la source)

2 citations Metrologia

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.