When investigating supermarket refrigeration systems, it is essential to consider the refrigeration load as it directly affects the required compressor capacity and energy consumption. Therefore, it is important to have knowledge of the refrigeration load and its main influencing factors. Direct usage …
de, dk (code pays fourni par la source)
Kenneth Leerbeck, Peder Bacher, Christian Heerup, Henrik Madsen
In many applications, e.g. fault diagnostics and optimized control of supermarket refrigeration systems, it is important to determine the heat demand of the cabinets. This can easily be achieved by measuring the mass flow through each cabinet, however that is expensive and …
Kenneth Leerbeck, Peder Bacher, Christian Heerup, Henrik Madsen
Aiming to enable robust large-scale fault diagnostics and optimized control for supermarket refrigeration systems, a data-driven grey box model for an evaporator and its surrounding cooling cabinet (or room) is presented. It is a non-linear model with two states: the cabinet temperature …
Kenneth Leerbeck, Peder Bacher, Christian Heerup, Henrik Madsen
In many applications, e.g. fault diagnostics and optimized control of supermarket refrigeration systems, it is important to determine the heat demand of the cabinets. This can easily be achieved by measuring the mass flow through each cabinet, however, that is expensive and …
The rebuilding of three Danish supermarket CO2 booster refrigeration plants with heat recovery heat exchangers is in the planning phase. The systems are situated in buildings heated by local district heating grids. The heating and cooling load characteristics have been analysed for …
Kenneth Leerbeck, Peder Bacher, Christian Heerup
Aiming to enable robust large-scale fault diagnostics and optimized control for supermarket refrigeration systems, a data-driven grey box model for cooling rooms and cabinets was developed. The analysis scopes a single cold room in a supermarket in Otterup (Denmark) and was done …
dk (code pays fourni par la source)
Niclas Laursen Brok, Torben Green, Christian Heerup, Shmuel S. Oren et autres
dk, us (code pays fourni par la source)
Nasrin Arjomand Kermani, John Terpollari Madsen, Christian Heerup, Brian Elmegaard
dk (code pays fourni par la source)
Nasrin Arjomand Kermani, John Terpollari Madsen, Christian Heerup, Brian Elmegaard
The presented study proposes a configuration combining the compression and condensation processes in a single unit and evaporation and expansion in another separate unit for application in a vapor compression heat pump cycle. The cycle includes injection of refrigerant into the compressor …
dk (code pays fourni par la source)
Supermarket refrigeration systems use a number of individual closed loop controllers, which are not interconnected, to optimise the overall system performance. The understanding of the interdependency between the individual controllers is the key to reap the harvest of the optimisation potential. In …
BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.