Aller au contenu principal
Profil bibliographique

Carter K. Asef

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

14Publications signalées
141Citations signalées
1Affiliations récentes

Les institutions déclarées

Les domaines associés

Metabolomics and Mass Spectrometry StudiesMass Spectrometry Techniques and ApplicationsGenetics, Aging, and Longevity in Model OrganismsAnalytical Chemistry and ChromatographyMetabolism and Genetic Disorders

Les publications récentes

Accès ouvert 2026 preprint OpenAlex

Online Buffer Exchange Coupled to Ion Mobility-Mass Spectrometry for the Rapid, Automated Analysis of Antibodies from Formulation

Michael R. Armbruster, Amanda R. Cicali, Carter K. Asef, Nicole A. Rivera-Fuentes et autres

Native ion mobility-mass spectrometry (nIM-MS) enables rapid protein structure and stability analysis, but adoption remains limited by time-consuming offline buffer exchange and manual static nanoelectrospray ionization (nESI) emitter workflows. This low throughput is incompatible with the demands of biotherapeutic development, where many …

us (code pays fourni par la source)

0 citations ChemRxiv
Accès ouvert 2026 article OpenAlex

Triboelectric Nanogenerator-Driven Laser Ablation Electrospray Ionization Enables Neutral Lipid Ionization and in Situ Double-Bond Localization

Joseph L. Corstvet, David W. Lewis, Dmitry Leontyev, Xin Ma et autres

Ambient ionization mass spectrometry includes numerous techniques, many of which are useful for analyzing lipids in biological samples. We report the development of a triboelectric nanogenerator (TENG)-driven laser ablation electrospray ionization (LAESI) platform, a novel ambient ionization method for the direct analysis …

us (code pays fourni par la source)

0 citations Journal of the American Society for Mass Spectrometry
Accès ouvert 2025 article OpenAlex

Discovery of Na v 1.7 Inhibitors through the Screening of Marine Natural Product Extracts

Adetola H. Adewole, Bhuwan Khatri Chhetri, Ghada M. Abdelwahab, Riya Bhanushali et autres

High Resolution Image Download MS PowerPoint Slide Automated high-throughput screening of a prefractionated extract library of marine macroorganisms identified 239 hits (hit rate 2.5%), including a marine algal extract that blocked the Na v 1.7 channel in a fluorescent-based flux assay. Bioactivity-guided …

us, bg (code pays fourni par la source)

1 citation Journal of Natural Products
Accès ouvert 2025 article OpenAlex

Beyond Targeted Newborn Screening: A Nontargeted Metabolomics Workflow to Investigate Birthweight–Metabolome Correlations

Carter K. Asef, Samuel G. Moore, Charles Austin Pickens, Carlos A. Saavedra‐Matiz et autres

High Resolution Image Download MS PowerPoint Slide Newborn screening (NBS) is one of the United States’ largest, most successful preventative public health initiatives, improving outcomes for newborns with inborn errors of metabolism. Most disorders on the Recommended Uniform Screening Panel are screened …

us, ru (code pays fourni par la source)

7 citations Analytical Chemistry
Accès ouvert 2024 article OpenAlex

Triboelectric Nanogenerators for the Masses: A Low-Cost Do-It-Yourself Pulsed Ion Source for Sample-Limited Applications

Carter K. Asef, Daniel D. Vallejo, Facundo Machado Fernández

Triboelectric nanogenerators (TENG) are useful devices for converting mechanical motion into electric current using readily available materials. Though the applications for these devices span across many fields, TENG can be leveraged for mass spectrometry (MS) as inexpensive and effective power supplies for …

us (code pays fourni par la source)

4 citations Journal of the American Society for Mass Spectrometry
Accès ouvert 2023 article OpenAlex

Unknown Metabolite Identification Using Machine Learning Collision Cross-Section Prediction and Tandem Mass Spectrometry

Carter K. Asef, Markace A. Rainey, Brianna M. Garcia, Gonçalo J. Gouveia et autres

Ion mobility (IM) spectrometry provides semiorthogonal data to mass spectrometry (MS), showing promise for identifying unknown metabolites in complex non-targeted metabolomics data sets. While current literature has showcased IM–MS for identifying unknowns under near ideal circumstances, less work has been conducted to …

us (code pays fourni par la source)

32 citations Analytical Chemistry
Accès ouvert 2022 article OpenAlex

CCS Predictor 2.0: An Open-Source Jupyter Notebook Tool for Filtering Out False Positives in Metabolomics

Markace A. Rainey, Chandler A. Watson, Carter K. Asef, Makayla R. Foster et autres

Metabolite annotation continues to be the widely accepted bottleneck in nontargeted metabolomics workflows. Annotation of metabolites typically relies on a combination of high-resolution mass spectrometry (MS) with parent and tandem measurements, isotope cluster evaluations, and Kendrick mass defect (KMD) analysis. Chromatographic retention …

us (code pays fourni par la source)

52 citations Analytical Chemistry
Accès ouvert 2022 article OpenAlex

An anchored experimental design and meta-analysis approach to address batch effects in large-scale metabolomics

Amanda O. Shaver, Brianna M. Garcia, Gonçalo J. Gouveia, Alison M. Morse et autres

Untargeted metabolomics studies are unbiased but identifying the same feature across studies is complicated by environmental variation, batch effects, and instrument variability. Ideally, several studies that assay the same set of metabolic features would be used to select recurring features to pursue …

us, br (code pays fourni par la source)

4 citations Frontiers in Molecular Biosciences
Accès ouvert 2022 preprint OpenAlex

Ion Mobility for Unknown Metabolite Identification: Hope or Hype?

Carter K. Asef, Markace A. Rainey, Brianna M. Garcia, Gonçalo J. Gouveia et autres

ABSTRACT Ion mobility (IM) spectrometry provides semi-orthogonal data to mass spectrometry (MS), showing promise for identifying unknown metabolites in complex non-targeted metabolomics datasets. While current literature has showcased IM-MS for identifying unknowns under near ideal circumstances, less work has been conducted to …

us (code pays fourni par la source)

2 citations bioRxiv (Cold Spring Harbor Laboratory)
Accès ouvert 2022 preprint OpenAlex

CCS Predictor 2.0: An Open-Source Jupyter Notebook Tool for Filtering Out False Positives in Metabolomics

Markace A. Rainey, Chandler A. Watson, Carter K. Asef, Makayla R. Foster et autres

Abstract Metabolite annotation continues to be the widely accepted bottleneck in non-targeted metabolomics workflows. Annotation of metabolites typically relies on a combination of high resolution mass spectrometry (MS) with parent and tandem measurements, isotope cluster evaluations, and Kendrick mass defect (KMD) analysis. …

us (code pays fourni par la source)

2 citations bioRxiv (Cold Spring Harbor Laboratory)
Accès ouvert 2022 article OpenAlex

In Silico Collision Cross Section Calculations to Aid Metabolite Annotation

Susanta Das, Kiyoto Aramis Tanemura, Laleh Dinpazhoh, Mithony Keng et autres

The interpretation of ion mobility coupled to mass spectrometry (IM-MS) data to predict unknown structures is challenging and depends on accurate theoretical estimates of the molecular ion collision cross section (CCS) against a buffer gas in a low or atmospheric pressure drift …

us (code pays fourni par la source)

29 citations Journal of the American Society for Mass Spectrometry
Accès ouvert 2022 preprint OpenAlex

An anchored experimental design and meta-analysis approach to address batch effects in large-scale metabolomics

Amanda O. Shaver, Brianna M. Garcia, Gonçalo J. Gouveia, Alison M. Morse et autres

ABSTRACT Large-scale untargeted metabolomics studies suffer from individual variation, batch effects and instrument variability, making comparisons of common spectral features across studies difficult. One solution is to compare studies after compound identification. However, compound identification is expensive and time consuming. We successfully …

us, br (code pays fourni par la source)

2 citations bioRxiv (Cold Spring Harbor Laboratory)

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.