Seismic proving test of BWR primary loop recirculation system
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The seismic proving test of BWR Primary Loop Recirculation system is the second test to use the large-scale, high-performance vibration table of Tadotsu Engineering Laboratory. The purpose of the test is prove the seismic reliability of the primary loop recirculation system (hereinafter abbreviated as PLR), one of the most important safety components in the BWR nuclear plants, and also to confirm the adequacy of seismic analysis method used in the current seismic design. To achieve the purpose, the test was conducted under conditions as near as possible to those for the actual systems using a test model of full scale with the structure as close as possible to that of the actual plants.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Seismic proving test of BWR primary loop recirculation system
- Date Crossref
- 14/01/2026
- Éditeur
- CRC Press
- Type
- book-chapter
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
The University of Tokyo pays non établi dans la noticeUniversité ou école supérieure
The University of Tokyo.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.