Geometry‐Encoded Soft Strain Sensing via Liquid‐Metal Transmission Lines
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Reliable strain sensing in soft systems remains challenging under mechanically complex conditions, where compression, folding, transverse deformation, and environmental perturbations often interfere with tensile-strain readout. Existing flexible strain sensors typically rely on amplitude-based electrical responses and therefore frequently require calibration, compensation, or signal reconstruction to isolate axial deformation. Here, we present a soft liquid-metal transmission-line sensor that directly encodes axial elongation into the time-of-flight of an electromagnetic pulse. Because the readout is governed by the total propagation path length, deformation modes that do not alter this path-including localized compression, folding, and biaxial transverse strain-produce negligible influence on the measured signal. The sensor exhibits linear strain response over a wide working range up to 400% strain, together with a strain-range-independent length resolution of 10 mm. Owing to its geometry-governed mechanism, the device enables self-referenced and calibration-free strain measurement with strong inter-device consistency, while maintaining stable operation under large pre-strain, cyclic loading, and irreversible deformation. Reliable sensing is further demonstrated on curved surfaces, wearable systems, inflatable structures, pneumatic artificial muscles, and task-level clinical tourniquet monitoring under dynamically varying deformation conditions. This work provides a robust and reconstruction-free strategy for strain sensing in soft electronics, wearable systems, and clinical healthcare.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Geometry‐Encoded Soft Strain Sensing via Liquid‐Metal Transmission Lines
- Date Crossref
- 16/09/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Xidian University pays non établi dans la noticeUniversité ou école supérieure
-
Xi'an Honghui Hospital pays non établi dans la noticeÉtablissement de santé
-
Xi'an Jiaotong University pays non établi dans la noticeUniversité ou école supérieure
Xidian University, Xi'an Honghui Hospital et Xi'an Jiaotong University.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.