Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Conservative dose remapping can be formulated by transporting mass and deposited energy across nonmatching grids, but fixed high-sampling calculations use the same work for easy and difficult cases. We developed conformal multiresolution error control (CoMERC), a fail-closed multilevel quasi-Monte Carlo (QMC) controller for reference-relative target-cell allocation error in a fixed piecewise-constant source model with known deformation. Two randomized nested replicates were evaluated at a probe level of 4 and candidate levels of 8 and 16. Four endpoints were controlled jointly: reference-mass-weighted global, high-gradient, and density-gradient-threshold root-mean-square error, plus eligible-cell maximum absolute error. A split-conformal multiplier was calibrated from 240 synthetic cases, frozen, and evaluated on 400 independent cases from the same generator and 120 cases from a prespecified shifted generator. In the primary set, joint coverage was 394/400 (98.50%; one-sided 95% lower limit, 97.06%), 388/400 cases (97.00%; lower limit, 95.18%) received an output, and 0/388 released outputs exceeded any tolerance (one-sided 95% upper limit, 0.769%). Final actions were level 8 for 190 cases, level 16 for 198, and ABSTAIN for 12. The frozen policy implied mean relative production-sample work of 0.5844 compared with always running both randomized replicates through level 16; the prespecified 95th-percentile bootstrap upper limit was 0.6194. All seven primary gates passed. In the shifted-generator set, 113/120 cases were released and one released output exceeded a tolerance. CoMERC provided marginal finite-sample error control and lower modeled production-sample work in the locked synthetic population, but not patient-level, registration-level, conditional-on-release, or clinical safety validation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Où se fait cette recherche

  • Arizona Research Center pays non établi dans la notice
    Structure de recherche
  • Independent Researcher pays non établi dans la notice
    Institution

Arizona Research Center et Independent Researcher.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Radiotherapy TechniquesMedical Imaging Techniques and ApplicationsRadiation Dose and Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.