Aller au contenu principal
Accès ouvert déclaré 2026 dataset

Are Hybrid Quantum Medical Image Classifiers Robust to NISQ Noise? A Leakage-Controlled Calibration and Finite-Shot Audit

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : pk, ae, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

This repository contains the supplementary material, detailed experimental results, statistical analyses, and reproducibility files supporting the study “Are Hybrid Quantum Medical Image Classifiers Robust to NISQ Noise? A Leakage-Controlled Calibration and Finite-Shot Audit.” The study investigates the robustness of hybrid quantum–classical medical image classifiers under simulated noisy intermediate-scale quantum (NISQ) conditions. Experiments were conducted using BreastMNIST and PneumoniaMNIST, with frozen ResNet18 feature extraction followed by train-only preprocessing and PCA-based dimensionality reduction. Two quantum learning approaches—a variational quantum classifier (VQC) and a ZZ-feature-map quantum kernel classifier (QSVM-ZZ)—were evaluated alongside classical machine-learning baselines. The supplementary package provides detailed results for depolarizing, amplitude-damping, phase-damping, bit-flip, and combined quantum noise channels across multiple noise levels. It also includes prediction-drift analyses, calibration and discrimination metrics, runtime information, and finite-shot sensitivity experiments covering 64, 128, 256, 512, and 1024 shots. The finite-shot analysis contains 108,000 evaluation records generated across repeated Monte Carlo simulations. The repository includes: Publication-ready supplementary material containing Tables S1–S7 Leakage-audit and cleaned-split information Classical baseline results Complete VQC and QSVM-ZZ channel-noise results Holm-corrected statistical-test outputs Prediction label-flip and probability-drift analyses Finite-shot sensitivity summaries and complete finite-shot results Runtime comparisons Experimental configuration and run-state files The files are provided to support transparency, reproducibility, independent verification, and secondary analysis of the reported experiments. The original medical imaging datasets are not redistributed in this repository; BreastMNIST and PneumoniaMNIST are publicly available through MedMNIST.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Où se fait cette recherche

  • Superior University pays non établi dans la notice
    Université ou école supérieure
  • Higher Colleges of Technology pays non établi dans la notice
    Université ou école supérieure
  • Manchester Metropolitan University pays non établi dans la notice
    Université ou école supérieure

Superior University, Higher Colleges of Technology et Manchester Metropolitan University.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.