Prognostic Value of Angiography‐Derived Fractional Flow Reserve Following Drug‐Coated Balloon Angioplasty
Rattachement africain : us, ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: The role of post-procedural physiological assessment after drug-coated balloon (DCB) percutaneous coronary intervention (PCI) remains poorly defined. Angiography-derived indices such as μQFR provide a non-wire-based alternative to traditional physiological measurements, yet their prognostic value following DCB-PCI has not been established. AIMS: To explore the association between post-procedural μQFR and target lesion revascularization (TLR) in patients undergoing DCB angioplasty for de novo coronary lesions. METHODS: This analysis included consecutive patients from the prospective SIROOP registry undergoing DCB-PCI for de novo coronary lesions. Post-procedural μQFR was assessed offline using a dedicated angiography-derived physiology software (AngioPlus, Pulse Medical Imaging Technology, Shanghai, China). Patients were stratified according to a post-procedural μQFR cutoff of 0.80 (≤ 0.80 vs. > 0.80). The primary endpoint was clinically driven TLR at 2-year follow-up. RESULTS: A total of 205 patients were analyzed, of whom 51 (24.9%) had a post-procedural μQFR ≤ 0.80 and 154 (75.1%) had a μQFR > 0.80. Baseline clinical characteristics were similar between groups. During 2-year follow-up, TLR occurred in nine patients (4.4%). Kaplan-Meier analysis demonstrated no significant difference in TLR according to post-procedural μQFR groups (log-rank p = 0.488). CONCLUSIONS: In patients undergoing DCB-PCI for de novo coronary lesions, post-procedural angiography-derived physiological assessment using μQFR was not associated with clinically driven TLR at 2-year follow-up when applying a cutoff of 0.80. These findings underscore the need for prospective studies to clarify the role of angiography-derived physiology after DCB-PCI.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Prognostic Value of Angiography‐Derived Fractional Flow Reserve Following Drug‐Coated Balloon Angioplasty
- Date Crossref
- 09/09/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.