Numerical Investigation of Cavity-Width Effects on the Thermal Performance of a Mechanically Ventilated Double-Skin Façade
Rattachement africain : Tunisie, fr, se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Double-skin façades (DSFs) offer a promising building-envelope strategy for improving thermal management by promoting heat’s removal from the façade cavity before it is transferred toward the indoor environment. This study numerically investigates the influence of cavity width on the thermo-fluid performance of a mechanically ventilated DSF under summer operating conditions. A two-dimensional computational fluid dynamics (CFD) model was developed using the RNG k-ε turbulence model together with the discrete ordinates radiation model. Mechanical ventilation was imposed through a velocity inlet of 0.765 m s−1, with an inlet air temperature of 17 °C and a solar radiation intensity of 365.4 W·m−2. The numerical model was validated against published experimental temperature measurements, yielding an average absolute relative error of approximately 5.65%. The validated model was subsequently applied to cavity widths ranging from 0.10 to 0.70 m. Increasing the cavity width substantially modified the airflow development and thermal field. The monitored temperature decreased from 31.66 °C at 0.10 m to 17.64 °C at 0.50 m, while further enlargement produced only minor reductions to 17.43 and 17.28 °C at 0.60 and 0.70 m, respectively. The total heat-transfer rate increased from approximately 1000 W at 0.10 m to a maximum of 1388 W at 0.50 m before slightly decreasing to 1379 and 1376 W at 0.60 and 0.70 m, respectively. This temperature reduction enhances heat removal from the façade cavity, helping to limit heat transfer toward the indoor environment and improve indoor thermal comfort under summer conditions. These results demonstrate a non-monotonic relationship between cavity width and heat-removal performance, with 0.50 m providing the highest heat-transfer rate among the investigated configurations. This result is specific to the geometry, boundary conditions, ventilation rate, and operating conditions considered in the present study. It should not be interpreted as a universally optimal cavity width for mechanically ventilated DSFs. The findings highlight the importance of cavity-width selection in the thermal management and design of mechanically ventilated DSFs for energy-efficient building envelopes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Numerical Investigation of Cavity-Width Effects on the Thermal Performance of a Mechanically Ventilated Double-Skin Façade
- Date Crossref
- 10/09/2026
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.