Simulation and Virtual Reality as Training Modalities in Interventional Radiology: A Systematic Review
Rattachement africain : gb, ie, us, au. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: To synthesise and appraise the certainty of evidence on simulation- and virtual-reality-based training in interventional radiology. MATERIALS AND METHODS: MEDLINE, EMBASE, Web of Science, and Scopus were searched to April 2026 following PRISMA 2020, under an a priori protocol registered with PROSPERO (CRD420261358144). Eligible studies evaluated simulation or virtual-reality training with objective outcomes. Risk of bias was assessed using design-specific tools (RoB 2, ROBINS-I, the NIH before-after tool) and certainty with GRADE. Heterogeneity precluded meta-analysis; findings were synthesised narratively (SWiM), without pooling. RESULTS: Eighteen studies (495 learners; seven randomised trials) were included; all reported improvement on at least one metric. Pre-post-reductions ranged from 50 to 72% (fluoroscopy time), 27 to 53% (procedure time), 28 to 76% (contrast volume), and 31 to 71% (radiation dose) (p < 0.001 to 0.05). In controlled trials, simulation improved technique (for example fewer catheters advanced without a guiding wire, 25% versus 82%, p = 0.01) and reduced contrast volume (28.0 versus 40.0 mL, p < 0.01), whereas procedure time was rarely significant. Transfer studies reported real-patient gains, including superior first-attempt cannulation (16 versus 12 of 16, p < 0.05) and a 30% radiation-dose reduction during real CT-guided procedures (p < 0.001). No randomised trial was at low risk of bias; GRADE certainty was low for radiation- and contrast-related outcomes and very low for procedure time and clinical transfer. CONCLUSION: Simulation probably improves interventional-radiology technical performance, most clearly for radiation- and contrast-related outcomes, with low-certainty evidence of clinical transfer. Small samples, heterogeneity and probable publication bias limit the evidence; adequately powered multicentre trials reporting patient-level outcomes are needed. LEVEL OF EVIDENCE: Level 2a (Oxford Centre for Evidence-Based Medicine).
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Simulation and Virtual Reality as Training Modalities in Interventional Radiology: A Systematic Review
- Date Crossref
- 09/09/2026
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.