Aller au contenu principal
Accès ouvert déclaré 2026 article

Fabrication and evaluation of polypropylene/natural rubber dental clamps: a model-based comparative study of isolation quality and user satisfaction

0Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Conventional metal rubber dam clamps provide effective isolation but may be associated with gingival trauma, localized enamel stress concentration, and patient discomfort. Polypropylene/natural rubber (PP/NR, 90/10 wt%) blends have previously demonstrated favorable mechanical properties and resistance to repeated autoclave sterilization; however, the functional isolation performance of PP/NR clamps has not been established. This study evaluated the isolation quality and user satisfaction of a PP/NR rubber dam clamp compared with a commercial polymer clamp and a conventional metal clamp using a standardized dental simulator. Three clamp systems were evaluated: an experimental PP/NR clamp, a commercial polymer clamp (SoftClamp™), and a conventional metal clamp ( n = 10 clamps per group). Isolation quality, including sealing ability, retention efficacy, and linear slippage, was assessed on a simulated mandibular left first molar at baseline (T0) and after each of ten successive steam sterilization cycles (T1–T10). Differences among clamp types were analyzed using the Kruskal–Wallis test, whereas changes across sterilization cycles were evaluated using the Friedman test. User satisfaction was assessed by 12 dental specialists and analyzed using the Friedman test with post hoc pairwise comparisons. The PP/NR clamp showed sealing ability that was not statistically different from that of SoftClamp™ and the metal clamp at baseline ( p = 0.835) or after repeated sterilization ( p > 0.05). All clamp systems maintained four-point contact throughout the study. Linear slippage was significantly greater in the PP/NR clamp than in both comparator groups at all assessment intervals ( p < 0.001), with median displacement ranging from 0.10 to 0.16 mm. Repeated sterilization did not significantly affect sealing ability or slippage in any clamp system. No statistically significant differences were detected among the three clamp systems for most clinician-reported usability outcomes. However, the PP/NR clamp demonstrated greater linear displacement and required longer placement time than the conventional metal clamp. The novel PP/NR clamp demonstrated no statistically significant differences in sealing ability and four-point retention compared to both conventional metal and SoftClamp™ systems. However, the PP/NR clamp demonstrated greater slippage and longer placement times than the metal clamp.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Fabrication and evaluation of polypropylene/natural rubber dental clamps: a model-based comparative study of isolation quality and user satisfaction
Date Crossref
09/09/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Dental materials and restorationsInfection Control in HealthcareOral microbiology and periodontitis research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.