CT-Based Annular Measurements as a Predictor for Perceval Valve Size Selection

0Citations signalées — pas une note de qualité
18Institutions déclarées
10Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVE: This multicenter study evaluates the accuracy of preoperative multidetector computed tomography (MDCT) measurements in predicting the appropriate Perceval (CORCYM Srl, Milan, Italy) prosthesis size, developing a chart to support surgeons in identifying the correct valve size. METHODS: A multicenter retrospective study was conducted across 15 centers in 10 different countries. Inclusion criteria included preoperative MDCT imaging, meeting standardized technical specifications, and early postoperative clinical and hemodynamic outcomes, meeting the expected outcomes of a correctly sized valve. The K-means and receiver operating characteristic (ROC) analysis were applied to evaluate the sizing chart on 70% of the population, and their accuracy was verified on the remaining 30%. RESULTS: There were 338 patients (mean age = 72.8 ± 7.9 years, 50.6% male) analyzed for this study, with a distribution of implanted bioprosthetic valve sizes of small in 21.6%, medium in 39.6%, large in 26.0%, and extra-large in 12.7%. The perimeter-derived diameter was found to be the MDCT-derived anatomical parameter with best overall correlation with the prosthesis size, and the K-means method outperformed the ROC curve-based classification, with an accuracy of prediction at almost 70%. CONCLUSIONS: The analysis of CT-based annular measurements as a predictive tool for Perceval valve sizing represents a meaningful step forward in contemporary cardiac surgery. In our retrospective, multicenter, real-world cohort, preoperative aortic annulus dimensions obtained via MDCT showed a moderate predictive accuracy for tricuspid aortic valves, and intraoperative assessment remains essential. Future larger studies, improved MDCT quality, and artificial intelligence tools may help refine and improve predictive performance, also in bicuspid anatomies.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
CT-Based Annular Measurements as a Predictor for Perceval Valve Size Selection
Date Crossref
07/09/2026
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCardiac and Coronary Surgery Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.