A simple MRI-derived correction substantially reduces bias in caliper-based tumor volume estimation in subcutaneous tumor models

0Citations signalées — pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Accurate longitudinal quantification of tumor burden is critical in preclinical oncology studies. Calipers remain the standard tool, being fast, inexpensive and anesthesia-free, yet the conventional caliper equation systematically overestimates subcutaneous tumor volume, because caliper jaws enclose overlying skin and fatty tissue in external measurements. We quantified and corrected this bias in two breast cancer xenograft subtypes (HER2-positive and triple-negative), untreated and under neoadjuvant chemotherapy, using MRI-derived 3D volumetry as reference. In a derivation subset of 12 segmentations from 6 animals, spanning both subtypes and all imaging timepoints, principal component analysis of tumor-only and tumor-plus-skin masks yielded a constant tissue offset of 1.04 mm. This offset represents the summed non-tumor tissue on both tumor sides and is therefore subtracted once per caliper dimension ( \(\delta \) ~ 1 mm). The corrected equation was evaluated on the remaining 106 paired measurements (47 animals, 5 to 1700 mm 3 ). The conventional equation overestimated volume by 158% (< 100 mm 3 ) to 54% (> 400 mm 3 ) with significant proportional bias ( p < 0.001). The MRI-corrected equation reduced mean relative overestimation from 50 to 21% and eliminated proportional bias (p = 0.99). Variance ratios of 1.47–1.73 indicated improved statistical power and reduced animal numbers, directly supporting the 3Rs principle and doubling-time (DT) estimates improved by up to 24%. The MRI-corrected equation improves tumor volume accuracy while preserving the simplicity, speed, and low cost of caliper measurements.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A simple MRI-derived correction substantially reduces bias in caliper-based tumor volume estimation in subcutaneous tumor models
Date Crossref
07/09/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Breast Cancer Treatment StudiesLymphatic System and DiseasesCutaneous Melanoma Detection and Management

BNTIC News n’est pas le producteur de ces données. Exploration à la demande auprès d’OpenAlex, avec contrôle bibliographique public par Crossref. Aucun service payant requis, aucune réponse conservée. Sources et limites.