Aller au contenu principal
Accès ouvert déclaré 2026 article

Electrochemical–LSPR Multiplexed Immunoassay with a Multi-Analyte Index for Sepsis-Associated Biomarkers

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : gb, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Multiplexed immunoassays frequently face challenges associated with signal cross-reactivity, matrix effects, and the integration of analytes with disparate concentration ranges and transduction efficiencies. Here, we report an electrochemical multiplexed immunoassay implemented on a four-working-electrode screen-printed carbon electrode (4-WE SPCE) platform, which was complemented with localized surface plasmon resonance (LSPR). Distinct redox probes─methylene blue (MB), cysteine (Cys), and ruthenium hexamine chloride (RuHex) were assigned to individual working electrodes, enabling parallel differential pulse voltammetry (DPV) measurements of three inflammatory biomarkers in phosphate-buffered saline (PBS) and 50% human serum. Blank samples were analyzed separately, and the nonzero calibration ranges were 0.5–20 ng mL–1 for procalcitonin (PCT) and 0.5–20 μg mL–1 for both C-reactive protein (CRP) and serum amyloid A (SAA). The bioassay demonstrated concentration-dependent current suppression, with calculated limits of detection (LoDs) of 0.0255 ng mL–1 for PCT, 1.60 μg mL–1 for CRP, and 0.0670 μg mL–1 for SAA in PBS, and 6.99 ng mL–1 for PCT, 0.0556 μg mL–1 for CRP, and 0.193 μg mL–1 for SAA in 50% human serum. Minimal cross-reactivity between biomarkers was observed, supporting analytical selectivity, while the measurements showed repeatability across replicate experiments (n ≥ 3). Gold nanoparticle (AuNP) surface engineering enhanced electron-transfer kinetics and antibody immobilization, producing analyte-specific electrochemical signatures. Complementary LSPR measurements provided an orthogonal optical readout that offered evidence of antibody–antigen binding at the plasmonic interface, strengthening confidence in assay specificity and performance. To support multiplexed signal integration, a dimensionless multianalyte index (MAI) based on normalized concentrations was introduced as a proof-of-concept analytical framework for combining heterogeneous biomarker signals. This MAI framework enables standardized interpretation of multiplexed electrochemical measurements using sepsis-associated inflammatory biomarkers, highlighting its potential applicability to broader multiplexed immunoassay platforms.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Electrochemical–LSPR Multiplexed Immunoassay with a Multi-Analyte Index for Sepsis-Associated Biomarkers
Date Crossref
06/09/2026
Éditeur
American Chemical Society (ACS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced biosensing and bioanalysis techniquesElectrochemical Analysis and ApplicationsElectrochemical sensors and biosensors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.