We are now installing two orthogonal laser strainmeters, each of which has a length of 100m, in a deep tunnel at the Kamioka Mine, Gifu prefecture. The laser frequency is locked on an iodine absorption band of saturation spectroscopy and the stability of ~ 10-13 isattained. The light paths of the laser strainmeter system are enclosed in stainless steel pipes. Inside pressure is kept to be 10-5 Pa.Consequently, quantitative measurement of crustal strains of the order of 10-13 becomes possible by the laser strainmeter system atKamioka. This resolving power corresponds to that of the superconducting gravimeter. Therefore, we can expect to determineparameters of the fluid core resonance, core modes and core undertone etc.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Les sujets associés

Geophysics and Sensor TechnologyHigh-pressure geophysics and materialsearthquake and tectonic studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.