BACKGROUND: Tube occlusion after glaucoma drainage device (GDD) implantation is a recognized complication typically requiring surgical revision. The Aurolab Aqueous Drainage Implant (AADI) is a cost-effective device increasingly used in low- and middle-income countries, yet, to our knowledge, laser management of AADI tube blockage has not been reported. CASE PRESENTATION: Two consecutive cases of postoperative AADI tube obstruction were managed with Nd: YAG laser. Case 1 was an 11-year-old one-eyed girl with primary congenital glaucoma and a failed trabeculotomy-trabeculectomy who developed iris obstruction of a sulcus-placed AADI tube 10 months after implantation. Nd: YAG laser iridotomy restored tube patency. A transient intraocular pressure (IOP) spike, mild hyphema, and moderate anterior chamber reaction occurred and resolved spontaneously within 3 days. At 7 months, IOP remained 12 mmHg without anti-glaucoma medication and no re-occlusion. Case 2 was a 38-year-old one-eyed aphakic man with extensive flame burn, prior bilateral penetrating keratoplasty, and open-sky vitrectomy who developed vitreous tube occlusion 4 weeks after AADI implantation. Nd: YAG vitreolysis reduced IOP from 32 to 28 mmHg within 2 h. However, on day 16 post-laser, conjunctival erosion with plate exposure, bullous keratopathy, and tube migration developed in the setting of limbal stem cell deficiency, necessitating implant explantation. CONCLUSIONS: Nd: YAG laser may serve as a practical first-line rescue for iris- or vitreous-related obstruction of sulcus-placed GDD tubes in selected high-risk eyes, potentially avoiding immediate surgical revision. This approach is cost-effective and relevant in resource-limited settings. However, long-term success depends on the underlying ocular surface and structural condition of the eye.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Nd: YAG laser rescue of sulcus-placed glaucoma drainage device tube occlusion: a two-case series
- Date Crossref
- 03/09/2026
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.