Aller au contenu principal
Accès ouvert déclaré 2026 article

Critical flicker fusion frequency assessment: robustness across photopic illumination in experienced divers

0Citations signalées — pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Introduction Critical flicker fusion frequency (cFFF) is a rapid, noninvasive index of cortical arousal and visual-cognitive performance that has gained renewed interest in diving and other extreme environments. However, the extent to which ambient illumination and water submersion affect cFFF remains insufficiently characterized. Methods Nineteen experienced divers (10 females; 24 ± 3 years) completed cFFF testing on land and at 5 m water depth under bright (land: 138 ± 2.4 lx; water: 75 ± 14.8 lx) and dark (0 lx) conditions using a manually operated flicker device. Heart rate (HR) and heart rate variability (HRV) were recorded continuously. Results For cFFF, mixed-effects ANOVAs revealed a significant main effect of submersion (p=0.0485) but not illumination (p=0.0754), with higher values in submersion compared to land (+1.4 Hz). Heart rate variability showed a main effect for submersion (p=0.004, +30 ms in submersion) and posthoc differences in dark illumination (p=0.004, +41 ms in submersion). No effects were observed for heart rate or respiration rate. Age showed a low negative correlation with cFFF (r = −0.22 to −0.40) but not with heart rate or heart rate variability. Sex effects were negligible (|r|<0.32). Discussion Based on the current 10-minute exposure time, cFFF is robust between the applied illuminations, but small absolute effects were observed from submersion. For human performance and diving research, these findings highlight the importance of baseline measures under comparable environmental conditions to prevent obscuring genuine changes in alertness or cognitive performance. Exposure time and ambient illumination should be standardized or reported to improve comparability across studies and operational environments.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Critical flicker fusion frequency assessment: robustness across photopic illumination in experienced divers
Date Crossref
03/09/2026
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiovascular and Diving-Related ComplicationsMarine animal studies overviewUnderwater Vehicles and Communication Systems

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.