Aller au contenu principal
Accès ouvert déclaré 2026 article

Moment capacity of back-to-back cold-formed steel channel bolted joints: An experimentally validated design approach

0Citations signalées — pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Cold-formed steel (CFS) bolted joints formed with back-to-back channel sections are widely used in portal frame construction due to their efficiency and ease of fabrication. However, the discrete force transfer between individual channels produces non-uniform stress distributions within the joint region, leading to localised stress concentrations, shear lag effects, bimoment-induced stresses due to restrained warping, and premature web buckling. These effects can reduce the moment capacity of typical joints by up to 40% compared with the nominal capacity of the connected members; however, this reduction is not explicitly addressed in current CFS design standards, including AISI S100, AS/NZS 4600, and EN 1993–1–3, which treat member and joint capacities independently. To address this gap, this paper presents a comprehensive experimental and parametric investigation to quantify the capacity reduction in CFS bolted joints and provide a reliable design method for practical applications. A detailed finite element (FE) model was first developed and validated against experimental results from CFS portal frame joint tests. Subsequently, an extensive parametric study comprising over 3400 FE simulations was performed to capture the influence of cross-sectional non-dimensional slenderness, as well as a wide range of geometric, material, and joint parameters. Based on these findings, a simplified design equation is proposed to enable reliable prediction of the reduced moment capacity of back-to-back channel bolted joints. The application of the proposed design equation is then verified against both numerical and experimental results of CFS frames, demonstrating excellent accuracy, with predictions within 1–3% of the actual capacities on average and coefficients of variation ranging from 0.06 to 0.09.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Moment capacity of back-to-back cold-formed steel channel bolted joints: An experimentally validated design approach
Date Crossref
01/11/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Structural Load-Bearing AnalysisStructural Engineering and Materials AnalysisFire effects on concrete materials

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.