Aller au contenu principal
2026 article

Hemocompatible polymer coating for extracorporeal circulation circuit affects lactate levels during cardiopulmonary bypass surgery

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Introduction Blood lactate level (LL) is a useful predictor of physiological issues during extracorporeal circulation (ECC) treatment. To determine variations in LL depending on the hemocompatible coatings used for ECC, in vitro experiments were performed using whole human blood samples. Methods Three types of experimental circuits were used, consisting of polymer-coated (PC), heparin-coated (HC), or noncoated (NC) membrane oxygenators ( n = 5), in which blood was circulated while heparin diluted with a glucose solution was continuously administered. Blood was collected at 0, 1, 3, 6, 12, and 24 h of circulation to measure LL, glucose level (GL), partial pressure of oxygen (PO), and oxygen saturation (SA) in each experiment. Each value was categorized according to coating type and compared using two-way repeated-measures or one-way analysis of variance. Results The mean LL values at each time point were significantly lower in the PC circuits than in the HC and NC circuits, whereas those in the HC and NC circuits were not significantly different. The mean GL values at each time point were significantly lower in the NC circuits than in the PC and HC circuits, whereas those in the PC and HC circuits were not significantly different. The mean PO and SA values at each time point were not significantly different among the different coating types. Conclusions In ECC circuits, PC may inhibit lactate production because of its hemocompatibility. Additionally, NC may enhance glucose consumption; however, the underlying mechanism remains unclear. Further research on the relationship between NC and GL is warranted.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Hemocompatible polymer coating for extracorporeal circulation circuit affects lactate levels during cardiopulmonary bypass surgery
Date Crossref
02/09/2026
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac and Coronary Surgery TechniquesMechanical Circulatory Support DevicesHemoglobin structure and function

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.