Aller au contenu principal
Accès ouvert déclaré 2026 article

Fetal Magnetocardiography Using Optically Pumped Magnetometers: A Literature Review

0Citations signalées — pas une note de qualité
6Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Fetal magnetocardiography (fMCG) provides direct non-invasive assessment of fetal cardiac electrophysiology, enabling detailed evaluation of cardiac rhythm, conduction, and repolarization. However, the clinical adoption of conventional fMCG has been limited by its reliance on superconducting quantum interference device (SQUID) systems, which require cryogenic cooling and specialized infrastructure. Optically pumped magnetometers (OPMs) have emerged as a promising cryogen-free alternative with the potential to broaden access to fetal electrophysiological assessment. This review summarizes the technological evolution and early clinical evaluation of OPM-based fMCG through an analysis of original in vivo human studies published up to June 2026. Twelve eligible studies were identified and synthesized narratively. Advances in sensor design, magnetic shielding, acquisition strategies, and signal-processing algorithms have enabled SQUID-comparable signal quality and cardiac interval measurements while substantially reducing cryogenic and infrastructure requirements. OPM-fMCG has demonstrated the potential to assess fetal cardiac time intervals, heart rate variability, fetal movement, and clinically important arrhythmias, including congenital long QT syndrome, atrioventricular block, and supraventricular and ventricular tachyarrhythmias. However, the available evidence remains dominated by small, single-centre studies, with relatively few fetuses affected by clinically significant arrhythmias. Prospective multicenter clinical validation, protocol standardization, independent replication, and regulatory evaluation are therefore required before OPM-fMCG can be integrated into routine diagnostic pathways for pregnancies requiring advanced fetal electrophysiological assessment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Fetal Magnetocardiography Using Optically Pumped Magnetometers: A Literature Review
Date Crossref
02/09/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Atomic and Subatomic Physics ResearchNeonatal and fetal brain pathologyAdvanced MRI Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.