Aller au contenu principal
Accès ouvert déclaré 2026 article

Operational Degradation of Flooded Lead–Acid Storage Under Frequency Containment Reserve: Long-Term Evidence from a Hybrid Multi-Technology BESS

0Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Flooded lead–acid batteries continue to operate in utility-scale battery energy storage systems (BESSs), yet their long-term degradation under grid-frequency regulation remains poorly characterized by field evidence. This paper presents an eight-year, multi-indicator degradation analysis of a flooded Ortsfeste Kupferstreckmetall (OCSM) lead–acid string at the M5BAT hybrid BESS facility (RWTH Aachen University), covering five years of active Frequency Containment Reserve (FCR) operation (2017–2021) followed by three years of low-utilization reserve operation (2022–2025). Four complementary health indicators are derived from a shared one-second-resolution operational dataset: DC internal resistance (DCIR), DC and AC round-trip efficiency, coulombic efficiency, and inverter efficiency. Five years of continuous FCR service produced no statistically detectable degradation across any indicator. In contrast, the transition to prolonged high-state-of-charge, low-throughput standby coincided with a pronounced increase in DCIR and a decline of about 14 percentage points in DC round-trip efficiency (from about 88% in the FCR phase to 74.0% in 2024). Consistent trends across all indicators, together with stable inverter efficiency, attribute the observed deterioration to the electrochemical system rather than the power electronics. These findings indicate that prolonged standby operation, rather than active FCR cycling, coincided with the onset of accelerated aging in this flooded lead–acid string. The published open-access dataset provides a valuable basis for future benchmarking and cross-technology comparisons for stationary battery storage.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Operational Degradation of Flooded Lead–Acid Storage Under Frequency Containment Reserve: Long-Term Evidence from a Hybrid Multi-Technology BESS
Date Crossref
02/09/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced Battery Technologies ResearchAdvanced battery technologies researchAdvancements in Battery Materials

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.