Impact of Intraoperative Patient‐Specific 3D ‐Printed Temporal Bones: A Randomized Controlled Trial

0Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVE: To determine if intraoperative inspection of patient-specific 3D-printed TB models, as a supplement to standard imaging, affects the cognitive load of surgeons during cochlear implantation (CI). METHODS: This randomized controlled trial included 40 consecutive adult primary CI surgeries performed by seven attending and five trainee surgeons at a large CI center. Cases were randomized 1:1 to current standard with surgical planning based on imaging review (controls) or to current standard plus intra-operative inspection of a 3D-printed model (intervention). The primary outcome, intraoperative cognitive load, was measured using the Surgery Task Load Index (Surg-TLX) and analyzed with linear mixed-effects models. Secondary outcomes included ratings of model anatomy, utility, and user experience (Schlegel-questionnaire) and prediction of intraoperative challenges. RESULTS: Attending surgeons experienced lower overall cognitive load using 3D models versus controls (3.8 vs. 5.5; p < 0.01), driven by reduced physical fatigue (p = 0.01). Conversely, residents reported higher overall load (7.2 vs. 4.8; p = 0.02) with increased mental (p = 0.01) and physical fatigue (p < 0.001). Fellows showed no significant difference in overall load (8.2 vs. 8.0; p = 0.88) but noted lower case complexity (p = 0.02) offset by higher physical fatigue (p = 0.04). Models were viewed as accurate and useful, particularly for trainee education, anticipating case difficulty and anatomical boundaries. CONCLUSION: The clinical impact of intraoperative 3D-printed models during CI is modulated by surgical experience. For attendings, models act as high-fidelity references facilitating cognitive offloading, whereas they stimulate mental effort for trainees. Selective implementation is recommended to align use of models to surgical experience level to promote operative efficiency and surgical training. LEVEL OF EVIDENCE: Level II.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Impact of Intraoperative Patient‐Specific <scp>3D</scp> ‐Printed Temporal Bones: A Randomized Controlled Trial
Date Crossref
01/09/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Surgical Simulation and TrainingAnatomy and Medical TechnologyHearing Loss and Rehabilitation

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.