Evaluation of Radiopacity of Endosequence Bio-ceramic Sealer and AH Plus by Digital Radiography
Résumé fourni par la source
Radiopacity is a key requirement for endodontic sealers to allow radiographic distinction between obturation material and surrounding tooth structures. American National Standards Institute (ANSI) and American Dental Association (ADA) mandate a minimum of 3 millimetres of aluminium (mm Al). Objectives: To compare, in vitro, the radiopacity of Endo-Sequence BC Sealer versus AH Plus using digital radiography on extracted human single-rooted teeth. Methods: An experimental in vitro study was conducted at the Department of Operative Dentistry, Liaquat University of Medical and Health Sciences, Jamshoro. A total of 60 single‑rooted teeth were selected using a non-probability convenience sampling method and allocated into two groups (n=30 each) without randomization. Care was taken to ensure that the two groups were comparable in terms of tooth type and root morphology and obturated with gutta-percha plus either Endosequence BC or AH Plus. After 7 days at 37°C/100 % humidity, radiopacity was expressed as millimetres of aluminium (mm Al). Data were compared using an independent-samples t-test (α = 0.05). Results: The sample analyzed consisted of 60 samples (30 samples per group). AH Plus demonstrated significantly higher radiopacity (6.94 ± 0.46 mm Al) compared to Endosequence BC (3.83 ± 0.35 mm Al). The confidence intervals were not overlapping (AH Plus: 6.77 7.10 mm Al; Endosequence BC: 3.71 ± 3.96 mm Al). The difference was statistically very significant (p<0.01). Conclusions: AH Plus demonstrated significantly higher and more consistent radiopacity than Endosequence BC, offering superior radiographic contrast and a wider safety margin for clinical detection of obturation quality.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Evaluation of Radiopacity of Endosequence Bio-ceramic Sealer and AH Plus by Digital Radiography
- Date Crossref
- 31/08/2026
- Éditeur
- CrossLinks International Publishers
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.