Contact-Based Glucose Measurements Without Any Vector Network Analyzer

0Citations signalées — pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Most experimental RF/microwave glucose sensors have to operate in conjunction with a vector network analyzer (VNA). Not only is a VNA bulky and expensive, but the process of a VNA-based glucose measurement is extremely tedious. For the first time, a fully customized system has been developed to demonstrate the feasibility of contact-based glucose measurement without any VNA. Method: A sweeping RF synthesizer (LMX2595) was used for scanning a specific range of frequencies that covered the perturbed frequencies of a membrane-supported glucose sensing head (MSSH), which was around 1.3 GHz. During the frequency sweeping process, a gain–phase detector (AD8302) was used to capture the gain, which was one of the parameters for determining the MSSH’s reflection coefficients (S11). During the frequency sweeping process, the measured voltage gains and phases from the AD8302 module were serially sent to a computer, where the reflection coefficients were retrieved and smoothed with a Savitzky–Golay filter augmented with a multilevel neural network implemented in PyTorch 2.13.0. Results: The proposed system was able to conduct continuous measurements on glucose concentrations from 0 to 111 mg/dL with no VNA and no manual intervention. Moreover, it was able to generate highly reproducible results consistent with those of a commercial VNA. Conclusion: The proposed non-VNA glucose sensing system was able to continuously measure the concentrations of a glucose–water solution with results consistent with those of a VNA.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Contact-Based Glucose Measurements Without Any Vector Network Analyzer
Date Crossref
01/09/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Microwave and Dielectric Measurement TechniquesSpectroscopy Techniques in Biomedical and Chemical ResearchNon-Invasive Vital Sign Monitoring

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.