Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : tw, sg. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Aims: To biomechanically compare the stability of mini-plate and dual-screw fixation following minimally invasive distal metatarsal osteotomy for hallux valgus, with an emphasis on early-stage stability under clinically relevant loading conditions. Methods: Three fixation configurations were evaluated: mini-plate fixation with two (PS2) or three (PS3) locking screws and dual-screw fixation (DS). Finite element analysis (FEA) was performed to quantify displacement and stress distribution under controlled bending and torsional loading, providing insight into internal load transfer mechanisms not accessible experimentally. Fresh-frozen human cadaveric specimens then underwent distal chevron metatarsal osteotomy and fixation according to each configuration (n = 3 per group). Cyclic and static bending tests were performed to simulate early postoperative weightbearing, and displacement responses were recorded. FE predictions were compared with experimental displacement trends. Results: Under bending loads, both FEA and cadaveric testing consistently demonstrated that PS3 exhibited the smallest displacement, followed by PS2, with DS showing the greatest instability. FE analysis further revealed that mini-plate fixation reduced bone stress at the osteotomy site but increased implant stress, whereas DS showed higher bone stress concentration. Under torsional loading, FE results indicated lower displacement but higher bone stress in DS. Cadaveric cyclic tests confirmed the superior stability of PS3, showing the least displacement accumulation over 1,000 cycles (p < 0.05). In static testing, PS3 achieved the highest failure load (~423 N), followed by PS2 (~248 N), while DS showed the lowest (~205 N). Conclusion: Mini-plate fixation, particularly PS3, provides superior resistance to bending-induced micromotion compared with DS, with consistent agreement between FE predictions and experimental findings. FEA further elucidated internal stress distribution, highlighting increased bone stress concentrations in DS. Overall, mini-plate fixation offers a more stable and clinically reliable construct for maintaining correction during early postoperative weightbearing.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus
Date Crossref
01/09/2026
Éditeur
British Editorial Society of Bone & Joint Surgery
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Foot and Ankle SurgeryLower Extremity Biomechanics and PathologiesFacial Rejuvenation and Surgery Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.