Aller au contenu principal
Accès ouvert déclaré 2026 article

A prospective comparison of [⁶⁸Ga]Ga-FAPI-2286 and [¹⁸F]FDG PET/CT for evaluating viable brain metastases in lung cancer

0Citations signalées — pas une note de qualité
10Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Standard [¹⁸F]FDG PET/CT has suboptimal sensitivity for assessing viable brain metastases due to high physiological brain background. Fibroblast activation protein (FAP)-targeted PET, with minimal brain expression, may overcome this limitation. This study aimed to compare the diagnostic performance of [⁶⁸Ga]Ga-FAPI-2286 versus [¹⁸F]FDG PET/CT for detecting viable brain metastases in lung cancer and evaluate their complementary value. In this prospective intra-individual study, 24 lung cancer patients with brain metastases underwent both [⁶⁸Ga]Ga-FAPI-2286 and [¹⁸F]FDG PET/CT within 3 days. Images were independently and blindly reviewed by two senior nuclear medicine physicians. Diagnostic performance (sensitivity, specificity, accuracy) was evaluated per-lesion and per-patient against a composite reference standard (characteristic imaging features, ≥ 3-month follow-up, comprehensive clinical evaluation). Quantitative parameters (SUVmax, target-to-background ratio [TBR], background uptake [SUVbgd]) and complementary detection patterns were analyzed. Among 43 lesions (36 viable, 7 non-viable), [⁶⁸Ga]Ga-FAPI-2286 demonstrated significantly higher per-lesion sensitivity (83.3% vs. 75.0%, P = 0.032) and accuracy (86.0% vs. 79.1%, P = 0.002) than [¹⁸F]FDG. Per-patient sensitivity (89.5% vs. 73.7%, P = 0.004) and accuracy (91.7% vs. 79.2%, P = 0.003) were also superior. The AUC for [⁶⁸Ga]Ga-FAPI-2286 was 0.917 (95% CI: 0.834–0.999) versus 0.875 (95% CI: 0.772–0.978) for [¹⁸F]FDG ( P = 0.031). [⁶⁸Ga]Ga-FAPI-2286 provided dramatically higher TBR in viable lesions (85.39 ± 57.99 vs. 5.19 ± 2.56, P < 0.001) due to minimal physiological brain background (SUVbgd 0.09 ± 0.11). Dual-tracer imaging supplemented the detection of 15 viable tumor lesions in 9 patients that were missed by either single tracer alone, increasing per-lesion sensitivity to 100% and preventing potential underdiagnosis in 47.4% (9/19) of patients with viable disease. [⁶⁸Ga]Ga-FAPI-2286 PET/CT outperforms [¹⁸F]FDG in identifying viable brain metastases from lung cancer, primarily due to its exceptional tumor-to-background contrast. The complementary detection patterns of the two tracers suggest that combined use can minimize diagnostic omissions, supporting an integrative imaging paradigm for more accurate intracranial staging/restaging. Registered 10 October 2022, https://www.chictr.org.cn , ChiCTR2100044131.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A prospective comparison of [⁶⁸Ga]Ga-FAPI-2286 and [¹⁸F]FDG PET/CT for evaluating viable brain metastases in lung cancer
Date Crossref
31/08/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Peptidase Inhibition and AnalysisRadiopharmaceutical Chemistry and ApplicationsOrthopedic Infections and Treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.