Aller au contenu principal
Accès ouvert déclaré 2026 article

Patient characteristics and monitor alarms in a cardiac ICU: A retrospective cross-sectional study

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fi. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The purpose was to describe patient monitor alarm burden in a cardiac surgical intensive care unit and explore whether routinely available patient characteristics are associated with alarm frequency, type, and duration. Secondary objectives were to assess indirect signs of alarm fatigue and compare alarm rates with two previous studies using identical monitors in different clinical units. We retrospectively collected patient-monitor alarm data and patient characteristics over four consecutive weeks in the cardiac surgical intensive care unit of Helsinki University Hospital. The study population comprised 81 patients. Alarm data were analysed descriptively and modelled using negative-binomial regression. Patients produced 45,044 alarms, with a median alarm rate of 6.8 [4.8 to 10.8] alarms per patient per hour. Older age was associated with fewer alarms (IRR = 0.90, 95% CI 0.83 to 0.98, P < 0.05). ASA 5 classification was associated with more low- ETCO2 alarms (IRR = 9.05, 95% CI 3.37 to 27.88, P < 0.05). Smoking was associated with more low invasive blood pressure alarms (IRR = 1.94, 95% CI 1.05 to 3.90, P < 0.05). Alarm load was high, clinician interaction with alarms was limited, and many alarms were momentary. Alarm rates were similar across three clinically different units using identical monitors. Routinely available patient characteristics were associated with selected alarm patterns, but the findings are hypothesis-generating. Similar alarm rates across different units suggest that default settings may not reflect unit- or patient-specific monitoring needs. The results suggest low positive predictive value and possible alarm fatigue, supporting unit-level alarm review that incorporates patient-level alarm patterns and signal-quality improvement, with prospective validation before patient-specific alarm-management changes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Patient characteristics and monitor alarms in a cardiac ICU: A retrospective cross-sectional study
Date Crossref
29/08/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Healthcare Technology and Patient MonitoringSepsis Diagnosis and TreatmentIntensive Care Unit Cognitive Disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.